5-2
PL14.22EA
The White Balance Adjustment should be
performed when replacing the LCD Panel
or Digital Main CBA.
2. White Balance Adjustment
Purpose:
To mix red and blue beams correctly for
pure white.
Symptom of Misadjustment:
White becomes bluish
or reddish.
1. Operate the unit for more than 30 minutes.
2. Enter the service mode.
3. Press [VOLUME DOWN] button three times on the
remote control unit to select “Drive setting” mode.
“Drive-” appears in the screen.
4. Set the color analyzer at the CHROMA mode and
zero point calibration. Bring the optical receptor
pointing at the center of the LCD-Panel.
Note:
The optical receptor must be set
perpendicularly to the LCD Panel surface.
5. Press [3] button to select the “HDB” for High Drive
Blue adjustment. (“HDB” appears in the screen.)
6. Press [MENU] button. The internal Raster signal
appears in the screen. (“Internal (Single)” appears
in the upper right of the screen as shown below.)
7. Press [CHANNEL UP/DOWN] buttons to adjust
the color temperature becomes 12000°K
(x= 0.272 / y= 0.278 ± 0.003).
8. Press [1] button to select the “HDR” for High Drive
Red adjustment (“HDR” appears in the screen.)
and press [CHANNEL UP/DOWN] buttons to
adjust the color temperature.
9. If necessary, adjust the “HDB” or “HDR” again
10. Press [6] button to select the “MDB” for Middle
Drive Blue adjustment (“MDB” appears in the
screen.) and press [CHANNEL UP/DOWN]
buttons to adjust the color temperature.
11. Press [4] button to select the “MDR” for Middle
Drive Red adjustment (“MDR” appears in the
screen.) and press [CHANNEL UP/DOWN]
buttons to adjust the color temperature.
12. If necessary, adjust the “MDB” or “MDR” again.
ITEM
SPECIFICATION
Color temperature
x= 0.272 ± 0.003
y= 0.278 ± 0.003
Input Signal
Internal pattern
(30/50/80% raster)
Measurement point
Screen center
M. EQ.
CA-310 (KONICA MINOLTA
Luminance meter) or
measuring instrument as
good as CA-310.
Aging time
60min.
(Retail MODE/100IRE Raster
HDMI 1080i@60)
MODE setting of TV
Shipment setting/
Retail MODE
Ambient
temperature
25°C ± 5°C
Color Analyzer
Perpendicularity
To avoid interference from ambient
light, this adjustment should be
performed in a dark room.
Internal (Single)
HDB 0
Internal (Single)
MDB 0