An error with a designated error code never leads to a deadlock situation. It must always be diagnosable (e.g. error buffer via OSD or blinking LED).
In case a failure identified by an error code automatically results in other error codes (cause and effect), only the error code of the MAIN failure is displayed.
5.2.2 How to Read the Error Buffer
You can read the error buffer in following ways:
• On screen via the SAM/CSM (if you have a picture).
Example:
–
ERROR: 000 000 000 000 000
: No errors detected
–
ERROR: 013 000 000 000 000
: Error code 13 is the last and only detected error
–
ERROR: 034 013 000 000 000
: Error code 13 was detected first and error code 34 is the last detected (newest) error
• Via the blinking LED procedure (when you have no picture).
5.2.3 Error codes overview
In this chassis only “layer 2” error codes are available and point to problems on the SSB. They are triggered by LED blinking
when CSM is activated. Only the following layer 2 errors are defined:
5.2.4 How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
• By using the CLEAR command in the SAM menu
Summary of Contents for 43PUT6504/56
Page 31: ...7 Electrical Diagram 7 1 Block diagram ...
Page 34: ...Power SSB Bottom View R769 DVDD3V3 C128 3V3_TUNER ...
Page 35: ...8 IC Data Sheets 8 1 MT5806IFEQ IC U401 Scaler ...
Page 36: ...8 2 AD82072 LG48NRY IC U601 Audio ...
Page 37: ...8 3 SI2169 D60 GMR U718 ...
Page 71: ...9 7 E 715G9740 Keyboard control panel For 50 58 6604 43 6504 Series 9 7 1 Key ...
Page 83: ...10 2 6654 series 50 55 58 0030 1050 0036 50L WIFI02 50R 1056 1053 1184 0040 1184 1054 0063 ...