Remark:
1. Press following Key Combination to reset the “Op Hour”: “
Menu/Home
” + “
101011
” on the remote control transmitter.
2. Under main menu “NVM editor”, select “Service Data”, you can use the
UP/DOWN keys
to view and change the set Type number, the set
Production Number or the 18AC of a part.(The NVM-editor still has the same function as before, alpha-numeric entry.)
4.3 Factory mode:
Purpose
To perform extended alignments.
Specifications
Displaying and or changing Panel ID information.
Displaying and or changing Tuner ID information.
Error buffer clearing.
Various software alignment settings.
Testpattern displaying.
Public Broadcasting Service password Reset.
etc.
How to Activate the Factory mode
To activate the Factory mode, use the following method:
Press the following key sequence on the remote control transmitter: from the
“menu/home”
press
“1999”
, directly followed by the
“Back/Return”
button. Do not allow the display to time out between entries while keying the sequence.
After entering the Factory mode, we can see many items displayed,
use the
UP/DOWN
keys to display the next/previous menu items
Factory mode overview
Summary of Contents for 43PUS6503
Page 32: ...7 Electrical Diagram 7 1 Block diagram ...
Page 35: ...Power SSB Bottom View R726 1 8V EMMC R221 TUNER_LNB C105 TUNER_3 3V ...
Page 36: ...8 IC Data Sheets 8 1 MT5802VHEJ IC U401 Scaler ...
Page 37: ...8 2 AD82588B LG48NAY IC U601 Audio ...
Page 38: ...8 3 ST42WS 17 E AP TU101 8 4 TDQS A701F EUROPE TU201 ...
Page 39: ......
Page 84: ...9 11J 715G9740 Keyboard control panel For 43 50 6503 50 58 6203 Series 9 11 1 Key ...
Page 101: ...10 3 6203 series 50 58 0040 0030 0065 0030 1053 1054 WIFI02 0036 1056 1057 0063 ...
Page 103: ......