Alignments
8.
Important:
after having edited the option numbers as
described above, you
must
press OK on the remote control
before
the cursor is moved to the left!
8.5
Reset of Repaired SSB
A very important issue towards a repaired SSB from a service
repair shop, implies the reset of the NVM on the SSB.
A repaired SSB in service should get the service Set type
“00PF0000000000” and Production code “00000000000000”.
Also the virgin bit is to be set. To set all this, you can use the
ComPair tool.
42PFL7613D/12_1
41641 04108 04175 45160
10115 00098 00001 00000
131
42PFL7613D/12_2
41641 04108 04175 45160
10114 00098 00001 00000
130
42PFL7633D/12_1
41641 04108 04175 45160
10115 00098 00001 00000
131
42PFL7633D/12_2
41641 04108 04175 45160
10114 00098 00001 00000
130
47PFL7603D/10_1
41641 04108 04175 45160
10119 00098 00001 00000
135
47PFL7603D/10_2
41641 04108 04175 45160
10143 00098 00001 00000
159
47PFL7603H/10_1
41641 04108 04171 45160
10119 00102 00001 00000
135
47PFL7603H/10_2
41641 04108 04171 45160
10143 00102 00001 00000
159
CTN_alt BOM#
Options Group 1
Options Group 2
Displ. (code)