9-1
A17FYTR
TROUBLESHOOTING
Check for short-circuiting or leak on the load circuit,
and service it if defective.
The power cannot be turned on.
The fuse blows out.
FLOW CHART NO.1
FLOW CHART NO.2
Is normal state restored when once unplugged
power cord is plugged again after several seconds?
Check if there is any leak or short-circuiting on the
primary circuit component, and service it if defective.
(D610, D611, D612, D613, Q605, Q606, IC601,
T600)
Yes
No
Yes
Is the fuse (F600) normal?
See FLOW CHART No.2 <The fuse blows out.>
No
Yes
Is the AMP+24V line voltage normal?
No
Check each rectifying circuit of the secondary
circuit and service it if defective.
Check the presence that the primary component
is leaking or shorted and service it if defective.
Check the presence that the rectifying diode or circuit
is shorted in each rectifying circuit of secondary side,
and service it if defective.
After servicing, replace the fuse.
When the output voltage fluctuates.
FLOW CHART NO.3
Does the photocoupler circuit on the
secondary side operate normally?
No
Yes
Check IC650, D651 and their periphery circuit,
and service it if defective.
When buzz sound can be heard in the vicinity of power circuit.
FLOW CHART NO.4
Check if there is any short-circuit on the rectifying diode and the circuit in each rectifying circuit of the secondary side,
and service it if defective. (IC652, Q650, Q651, Q656, Q667, Q668, Q674, D650, D656, D657, D658, D659, D662, D674,
D680, D681, D690)
AMP+24V is not output.
FLOW CHART NO.5
Is approxi24V voltage supplied to the
cathode of D674?
No
Yes
Check C691, D651, D674 and their periphery
circuit, and service it if defective.
Check IC601, D614, D616, D617, D618 and their
periphery circuit, and service it if defective.