10-24
BA94N0F01012
Main CBA Top View [19PFL3504D/F7]
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de m
ê
me type de 4A, 125V.
4A/125V
Summary of Contents for 19PFL3504D/F7
Page 14: ...4 2 A91N2DC 2 Rear Cabinet S 1 1 Stand Assembly S 2 S 2 S 2 S 3 Fig D1 ...
Page 18: ...4 6 A9172DC 2 Rear Cabinet S 1 1 Stand Assembly S 2 S 2 S 2 S 3 Fig D1 ...
Page 46: ...10 3 A91N2SCM1 Main 1 4 Schematic Diagram 19PFL3504D F7 ...
Page 47: ...10 4 A91N2SCM2 Main 2 4 Schematic Diagram 19PFL3504D F7 ...
Page 48: ...10 5 A91N2SCM3 Main 3 4 Schematic Diagram 19PFL3504D F7 ...
Page 50: ...10 7 A9172SCM1 Main 1 4 Schematic Diagram 22PFL3504D F7 ...
Page 51: ...10 8 A9172SCM2 Main 2 4 Schematic Diagram 22PFL3504D F7 ...
Page 52: ...10 9 A9172SCM3 Main 3 4 Schematic Diagram 22PFL3504D F7 ...
Page 54: ...10 11 A91N2SCJ Jack Schematic Diagram ...
Page 55: ...10 12 A91N2SCF Function Schematic Diagram ...
Page 56: ...10 13 A91N2SCIR IR Sensor Junction Schematic Diagram ...
Page 71: ...10 28 BA91N2F01021 A Jack CBA Top View ...