Mechnical instructions
Step 5 : Removal power board
5-1 Remove 2 screws,1101 connector, and 8101 grouding wire
5-2 The gasket(3138 154 03270) was found in Fig.6.
Step 6 : Removal Scaler board
6-1 Remove 1 screw for fixed scaler- shield.
6-2 Remove D-SUB two screws.
then pull out scaler-
.
shield
Fig. 5
Fig.2 connector(1707)
Fig. 1
Front bezel
1. Front bezel removal
Hold lock bezel-right and lock bezel -left, then push the front
Bezel from down to up see Fig. 1
2. Control panel removal (Fig.2)
Step1. Remove the 7-pins connectors(1707)
Step2. Release two screws
3. Back cover removal
Step1. Release four screws see Fig.3
Step2. Pull out LG-frame panel then remove LG-frame to find out
Scaler board,power board and inverter board Fig. 4
Fig. 6
Fig. 7
Gasket
3138 154 03270
Fig. 3
Fig. 4
http://jdwxzlw.com/?fromuser=华盛维修