1-6-12
T6310EA
5. SECAM Black Level Adjustment
Purpose:
To set Black Level of the SECAM signal R-
Y/B-Y to Ref. level.
Symptom of Misadjustment:
If Black Level of the
SECAM signal R-Y/B-Y is incorrect, the picture is blu-
ish or reddish in grayscale compared with PAL signal.
1. Degauss the CRT and allow CRT to operate for 20
minutes before starting the alignment.
2. Input the SECAM Gray Scale signal from video
input.
3. Enter the Service Mode. (See page 1-6-9.)
4. To enter the C/D/S mode, press [
p
] on the
remote control unit.
5. To select SBR (SECAM Black Level R-Y), press [6]
button on the remote control unit.
6. Press [P+/P-] buttons to adjust Y signal to the black
ref. level.
7. To select SBB (SECAM Black Level B-Y), press [7]
button on the remote control unit.
8. Press [P+/P-] buttons to adjust Y signal to the black
ref. level.
6. V. Size Adjustment
Purpose:
To obtain correct vertical height of screen
image.
Symptom of Misadjustment:
If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
1. Enter the Service mode. (See page 1-6-9.)
Press [9] button on the remote control unit and
select V-S Mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [P+/P-] buttons on the remote control unit so
that the monoscope pattern is 90
±
5% of display
size and the circle is round.
7. V. Shift Adjustment
Purpose:
To obtain correct vertical position of screen
image.
Symptom of Misadjustment:
If V. position is incor-
rect, vertical position of image on the screen may not
be properly displayed.
1. Enter the Service mode. (See page 1-6-9.)
Press [9] button on the remote control unit and
select V-P Mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [P+/P-] buttons on the remote control unit so
that the top and bottom of the monoscope pattern
are equal to each other.
Test point
Adj. Point
Mode
Input
Pin 1 of
CN303
P+/P-
buttons
---
SECAM
Gray Scale
Tape
M. EQ.
Spec.
---
Pattern Generator
---
5mV/Div (10:1 Prove)
Y Signal
1H
1H
1H
Black REF. Level
Fig. 4
Test point
Adj. Point
Mode
Input
Screen
P+/P-
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
90
±
5%
Test point
Adj. Point
Mode
Input
Screen
P+/P-
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
90
±
5%