GENERAL PRODUCT SPECIFICATION
15" CM2300 GS-III CMTR
TYPE
: 105S21/89H (COCA)
BRAND : PHILIPS (60K)
8639 000 10601
00-05-12
00-05-12
590
19
28
MAY YU
B-2 Transportation standards
6.2 Display disturbances from external environment
6.2.1ESD Disturbances
According to EN50082-1 (also refer to IEC801-2 for detail).
6.3 Display disturbances to external environment
The disturbances induced by the display and tolerated by the environment are defined as follows :
6.3.1 Ionizetic radiation
Completely fulfilled International Commission of
Radio logical Protection (ICRP) requirement 0.5 mR/Hr.
Actually the set can reach 0.1 mR/Hr.
6.3.2 EMI
Can comply with FCC part 15, DOC C108.8 and EN55022
!
!
!
!
!
!
!
!
!
!
!
!
!
TRANSPORTATION TEST OF BU-MONITORS
1999/1/27
TEST ITEM
TEST CONDITION
STANDARD REFERENCE
1. PACKAGED TEST:
1.1 Packaged random vibra. test
l
5~200 Hz, 0.73 Grms,
l
30 MIN/ AXIS, 3 AXES.,
Ref. ASTMD-4169
1.2 Drop test
l
Gross weight drop height:
9.53~18.59 kg 61 cm
l
Sequence: 1C-3E-6F, 10 drops,
For main land China:
(exclude local for local)
l
Sequence: 1C-3E6F-
bottom side:30cm-
bottom side: 70cm-bottom side: 30cm-
bottom side: 80cm, 14drops,
NSTA
NSTA
NSTA + bottom 4 drops
1.3 Cold drop test
(Only for reference)
l
-10 C for 16 hours, recovery time after
cold test: +/- 5minutes
l
Gross weight drop height:
9.53~18.59 kg 61cm
l
Sequence: 1C-3F, 4drops,
1 set: C345-F4-F5-F3,
1 set: C261-F2-F6-F1
UN-D1400
NSTA
2. UN-PACKAGED VIBRATION TEST:
2.1 Operating random vibra. test
l
5~500Hz, 0.25 Grms,
l
30 min/axis 3 axes.
l
Frequency: (Hz): 5,350,500
G^2/ Hz: 0.001, 0.0001, 0.00005
Ref. OEM spec.
2.2 Shock test (half sine)
a. 120G, <3 msec, 6 shocks
l
G value measurement filter: 1000Hz
l
Exclude CRT impurity
b. 140 G, <3 msec, 6 shocks
(Only for reference)
Ref. OEM spec.
67
105S2 CM23 GSIII
http://jdwxzlw.5d6d.com/?fromuser=华盛维修