UK
UK
3
2
2. AVENT ISIS Breast Pump with VIA
Feeding System
Pump
a)
Funnel cover
b)
Let-down massage cushion
c)
Pump cover
d)
Silicone diaphragm
and stem*
e)
Handle
f)
Pump body and funnel
g)
White star valve*
3. To clean and sterilise your pump
Before you use your breast pump for the first time and every time
before use:
Separate all parts, then wash in the top shelf of the dishwasher or
in warm soapy water and rinse. Do not use antibacterial cleaners/
detergents. Sterilise in an AVENT Steam Steriliser (electric or
microwave), or by boiling for 10 minutes. If using
an AVENT Steam Steriliser, the pump will remain
sterile in the Steriliser for 3 hours provided the
lid is not removed.
4. To keep your pump sterile and
compact for travel
After sterilising all parts, you can clip the cover (a) over
the funnel and let-down massage cushion and screw
the travel cover (n) onto the pump body (f) in place of
the VIA Adaptor (h).
VIA Feeding System
h)
VIA Adaptor
i)
VIA Cup (6 oz/180 ml)
j)
VIA Lid/Stand
k)
Dome cap
l)
Newborn teat (0m+)
m)
Screw ring
n)
Travel cover
*spares included
5. Using your ISIS Breast Pump with
the AVENT Feeding Bottle
Simply replace the AVENT VIA Cup and Adaptor with
the AVENT Feeding Bottle. To make the pump completely
stable insert the bottle into the funnel cover (a).
6. How to assemble your AVENT
ISIS Breast Pump
Separate all parts and ensure pump has been cleaned and sterilised
as in section 3:
1) Wash your hands thoroughly. Click the white star valve (g) into the
pump body (f) from underneath making sure the flat side of the
valve is downwards and the star side is facing up.
2) Place the pump body (f ) onto the VIA Adaptor (h). Twist gently
clockwise until it catches.
DO NOT OVERTIGHTEN!
3) Place the assembled pump body and VIA Adaptor onto the VIA Cup (i).
Twist gently clockwise until it catches.
DO NOT OVERTIGHTEN!
4) Place the silicone diaphragm with stem (d) into the pump body (f).
Make sure it fits securely around the rim by pressing down with your
fingers to ensure a perfect seal. (This is easier if assembled while wet).
5) Place the forked end of the handle (e) under the diaphragm stem
(d) and push down gently on the handle until it clicks into place.
6) Carefully insert the let-down massage cushion (b) into the pump
funnel (f) making sure it is perfectly sealed all round the rim of
the funnel. (This is easier if assembled while wet).
7) Click the pump cover (c) onto the pump body (f). To make the pump
completely stable, insert the VIA cup into the VIA lid/stand ( j).
7170-VIA+ISIS-UKEPIL#1-pgs.qxd 25/11/04 9:38 Page 2