Philio PSM01 Manual Download Page 5

Installation

1. In the first time, add the device into the Z-Wave

TM

 network.  First,

make sure the primary controller is in the inclusion mode. And then

power on the device, just take out the insulation Mylar in the back side

of   the   device.   The   device   will   auto   start   the   NWI   (Network   Wide

Inclusion) mode. And it should be included in 5 seconds. You will see

the LED light ON one second.

2. Let Controller associate with Group 1 of the device, any light switch

that intend to be turned on when  the device  trig please associate to

Group 2 of  the device.

3.  In the accessory pack. There are two type of double coated tape,

one is thicker (hereinafter referred to as A tape)  and another is thinner

(hereinafter referred to as B tape), you can use A tape for the test at

the beginning. The right way for A tape installation is stick it to the

position below tamper key. The thicker tape won't let the tamper key

close, so the sensor will enter the test mode, You may test if installed

position is good or not by this way.

After finish the test and decide to fix, then you can remove tape A, and

mounting the sensor by using tape B.  This will close the tamper key

and let the sensor enter normal mode.

Z-Wave Configuration Settings

Notice: The data size of the configuration settings is 1.

NO.

Name

Default

Valid

Values

Description

2 Basic Set Level 255

1~100,

0xFF

Setting the BASIC command value to 
turn on the light. The 0xFF(-1) means 

5

Summary of Contents for PSM01

Page 1: ...in the front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusio...

Page 2: ...p the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Door Window Report When the Door Window state changed the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Door Window 0x0A Sensor Value 0x00 is closed 0xFF is opened Tamper Report When the 2 tamper keys in t...

Page 3: ...on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to save...

Page 4: ...low steps 1 Using a tool like 1 to press 1 1 till hear a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 Don t let the device facing the window or the sunlight 4 ...

Page 5: ... tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After f...

Page 6: ...t3 Reserved Bit4 Disable delay 5 seconds to turn off the light when door window closed Bit5 Disable auto turn off the light after door window opened to turn on the light Bit6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds 9 Turn Off Light Time 4 4 127 A...

Page 7: ...tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient ...

Page 8: ...ng the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 8 ...

Reviews: