background image

Z-Wave Supported Command Class

Command Class

Version

Required Security Class

Z-Wave Plus™ Info

2

None

Security

1

None

Security 2

1

None

Supervision

1

None

Transport Service

2

None

Association

2

Highest granted Security Class

Association Group 
Information

3

Highest granted Security Class

Device Reset Locally

1

Highest granted Security Class

Firmware Update Meta 
Data

5

Highest granted Security Class

Indicator

3

Highest granted Security Class

Manufacturer Specific

2

Highest granted Security Class

Multi-Channel Association

3

Highest granted Security Class

Powerlevel

1

Highest granted Security Class

Version

3

Highest granted Security Class

Configuration

4

Highest granted Security Class

Sensor Multilevel

11

Highest granted Security Class

Basic

1

Highest granted Security Class

Notification

8

Highest granted Security Class

Sound Switch

1

Highest granted Security Class

Battery

1

Highest granted Security Class

Warning

  

Caution, 

avoid listening at high volume levels for long
periods

CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery according to the instructions.

Choosing a Suitable Location

1.

The   suitable   ambient   temperature   for   the   module/device   is
0°C~40°C.

2. Do NOT place the module/device direct under sunlight, in a humid

place or in any location where they may contact moisture, dirt, dust.

3.

Do   NOT   place   the   module/device   where   exists   combustible
substances or any source of heat, fires, radiators, boiler etc.

Disposal

This marking indicates that this product should not 
be disposed with other household wastes throughout
the EU. To prevent possible harm to the 
environment or human health from uncontrolled 
waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return 
your used device, please use the return and 
collection systems or contact the retailer where the 
product was purchased. They can take this product 
for environmentally safe recycling.

Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 
24257, Taiwan(R.O.C)

w

   ww.philio-tech.com

 

 

8

Summary of Contents for PSE04-A

Page 1: ...gardless of vendor to increase reliability of the network The device adopt the Z WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communicatio...

Page 2: ...orrect type that can defeat a safeguard for example in the case of some lithium battery types disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extreme...

Page 3: ...y Installation When the device report the low battery message The user should replace the battery to new one The battery type is AA 1 5V Please loosen the screw on the back cover to release the front cover 3 ...

Page 4: ...ey in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment SmartStart process or you can s...

Page 5: ...ce will unsolicited to send the Notification Report to the nodes in the group 1 Notification Report V8 Notification Type Siren 0x0E Event Siren active 0x01 Siren idle 0x00 Temperature Report When the temperature differential over the device will unsolicited to send the Sensor Multilevel Report to the nodes in the lifeline group Sensor Type Temperature 0x01 Temperature differential report This func...

Page 6: ...that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low device will report low battery even every 30 minutes...

Page 7: ...und duration 1 tick is 30 seconds 3 Customer Function 0x00 All Customer function switch using bit control 0 Bit0 Disable Trigger Alarm 0 Enable 1 Disable 0 Bit1 Disable Sound Only using optical alarm 0 Enable 1 Disable 0 Bit2 Temperature Unit 0 Fahrenheit 1 Celsius 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 4 Auto Report Temperature Time 0x0C 0 255 The interval time...

Page 8: ...oid listening at high volume levels for long periods CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 0 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture di...

Page 9: ...rient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 This device may not cau...