Learning
When PAN45 is in learning mode, LED flashes on and off alternately and
repeatedly at 0.5 second intervals.
Zigbee
State Type
LED Indication
Tx/Rx
Flash 1ms.
No node ID
Under normal operation, when the Switch has not been allocated a node ID,
the LED flashes 0.5s every 3s last for 3 minutes.
Learning
When Zigbee is in learning mode, LED flashes on and off alternately and
repeatedly at 0.5 second intervals.
Learning
complete
LED 1s on, 1s off 3 times.
Learning fail
LED 0.3s on, 0.3s off 5 times
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source
of heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of
which phenomenon is normal.
Installation
1. Plug this On/Off Switch into a wall outlet near the load to be controlled.
2. Plug the load into the Switch. Make sure the load to be controlled cannot
exceed 13A.
3. Press the button or switch on the load to the ON position.
4. To manually turn ON the Switch, press and release the On/Off button. The
LED will turn ON, and the load plugged into the Switch will also turn ON.
5. To manually turn OFF the Switch, simply press and release the On/Off but-
ton. The LED will turn OFF and the load plugged into the Switch will also
turn OFF.
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of
the Z-Wave system.
1-1 BASIC_GET / BINARY_SWITCH_GET
Upon receipt of the following commands from a Z-Wave Controller, the
Switch will report its On/Off state to the node asked.
Basic Get Command:
[Command Class Basic, Basic Get]
Basic Report Command:
Report OFF:
[Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:
[Command Class Basic, Basic Report, Value = 255(0xFF)]
Binary Switch Get Command:
[Command Class Switch Binary, Switch
Binary Get]
Binary Switch Report Command:
Report OFF:
[Command Class Switch Binary, Switch Binary Report,
Value =0(0x00)]
Report ON:
[Command Class Switch Binary, Switch Binary Report,
Value = 255(0xFF)]
1-2 BASIC_SET / SWITCH_BINARY_SET
Upon receipt of the following commands from a Z-Wave Controller, the load
attached to the Switch will turn on or off.
[Command Class Basic, Basic Set, Value = 1~99,255(0xFF)]
: the load