Installation and Operation
1. Plug this switch into a wall box near the load to be controlled.
2. Connects the load to the switch. Make sure the load to be controlled cannot
exceed 16A (Resistive Load).
3. Press the button or switch on the load to the ON position.
4. To manually turn ON the switch, short press the “
” button. The green “
” LED
will turn ON, and the blue timer LEDs will also turn ON. Every passed 10 minutes
will change one blue LED as a green LED. When all the blue LEDs changes, all
the green LEDs will blink twice and turn off. Then the switch turns off and green
“
” LED changes to red “
” LED.
5. To manually turn OFF the Switch, short press the “
” button. The red LED will
turn ON and the load connected to the switch will also turn OFF.
6. Every short press “
┿
” button, there will be increasing one more blue LED. When
arrives to the intended timer, stop pressing and all the blue LEDs will blink twice.
Or you can press and hold “
┿
” button, there will be increasing one more blue LED
every half second. Every blue LED represents 10 minutes working time of switch.
The maximum time is 110 minutes, and the default is 60 minutes.
7. Every short press “
━
” button, there will be decreasing one blue LED. This means
the working time of switch decrease 10 minutes. The minimum time is 10 minutes.
Or you can press and hold “
━
” button, there will be decreasing one blue LED
every half second.
8. After switch is turned on for a while, you can still decrease (or increase) the
working time by pressing “
━
” button (or “
┿
” button). When all the blue LEDs
decreases to off, the switch will turn off.
Programming
1. Basic Command Class / Binary Switch Command Class
PAN24 will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1-1 BASIC_GET / BINARY_SWITCH_GET
Upon receipt of the following commands from a Z-Wave Controller, PAN24 will
report its On/Off state to the node asked.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]
Binary Switch Get Command:[Command Class Switch Binary, Switch Binary
Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
255(0xFF)]
1-2 BASIC_SET / SWITCH_BINARY_SET
Upon receipt of the following commands from a Z-Wave Controller, the load
attached to PAN24 will turn on or off.
[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]: the load attached
to the switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to the
switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99, (255)0xFF]:
the load attached to the switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load
attached to the switch turns off.
1. Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to associated Z-Wave devices. It supports
one association group with one node support for Grouping 1. For group 1, the Switch
will report its latest status to Z-Wave Controller.
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT,
ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.
2-1 Auto report to Grouping 1 (Maximum Node 5)