background image

 

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]

 

Meter Report Command: 
[Command Class Meter

Meter Report

Rate Type = 0x01

Meter Type = 0x01

Precision = 2

Scale = 6

Size = 1

Meter Value(PF)

 

 
Example: 
Scale = 0x06 (PF) 
Precision = 2 
Size = 1 (PF) 
Meter Value 1 =    0x63(PF)    (It means that the load power factor is 0.99) 
 
3.    Z-Wave’s Configuration

 

 

Configuration 

Parameter 

Function 

Size 

(Byte) 

Value 

Unit 

Default 

Description

 

Watt Meter 

Report Period 

0x01- 

0x7FFF 

5s 

720 

720*5s=3600s=1 hour

 

KWH Meter 

Report Period 

0x01- 

0x7FFF 

10min 

6*10min=1 hour

 

Threshold of 
current for Load 
caution 

10-1300 

0.01A 

1300 

1300*0.01A = 13A

 

Threshold of 
KWh for Load 
caution 

1-10000 

1KWh 

10000 

 

Restore switch 
state mode 

0-2

 

 

 

0 : Switch off 

1 : Last switch state 

2 : Switch on

 

Mode of Switch 
Off function 

0-1 

 

0 : Disable 

1 : Enable

 

LED indication 
mode 

1-2 

 

1 : Show switch state 

2 : Show night mode

 

Auto off timer 

0-0x7FFF 

1s 

0 : Disable auto off 

function 

1-0x7FFF : 1s ~ 32767s

 

RF off 
command mode 

0-3 

 

0 : Switch off 

1 : Ignore 

2 : Switch toggle 

3 : Switch on

 

11 

Switch Status 
Report mode 

0-1 

 

0 : Disable 

1 : Enable 

 

3-1

 Watt 

Meter Report Period: 

    If  the  setting  is  configured  for  1hour  (set  value  =720),  the  PAN15  will  report  its 

instant power consumption every 1 hour to Group1 node.    The maximum interval 

to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 

3-2 KWH Meter Report Period: 

      If  the  setting  is  configured  for  1hour  (set  value  =6),  the  PAN15  will  report  its 

Accumulated  Power  Consumption  (KW/h)  every  1  hour  to  Group1  node.    The 

maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 

days (10min*32767/1440=227.55 days). 

3-3 Threshold of current for Load Caution 

This is a warning when the current of load over the preset threshold value, if the 

setting value is 1300, when the load current of Relay1 over this value, PAN15 

will send current meter report to warn the Group1 node, the Range of the setting 

value is from 10 to 1300,and the default value is 1300. 

3-4 Threshold of KWh for Load Caution 

This is a warning when the KWh of load over the preset threshold value, If the 

setting value is 10000, when the Accumulated Power Consumption of Relay1 over   

this value, PAN15 will send KWH meter report to warn the Group1 node, 

minimum value is 1KWh and default value is 10000 kWh. 

3-5 Restore switch state mode : 

  Whenever the AC power return from lost, PAN15 will restore the switch state which 

could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The default setting 

is LAST SWITCH STATE. 

3-6 Mode of switch off function : 

  When  the  mode  of  switch  On/Off  is  set  to  0,  any  command  of  switch  off  will  be 

disabled  and  the  On/Off  function  of  include  button  will  be  disabled.  The  default 

setting is enable mode.   

Summary of Contents for PAN15-2

Page 1: ... switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall o...

Page 2: ...d intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not...

Page 3: ...uping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Pr...

Page 4: ... Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 4 Size 2 Meter Value V Example Scale 0x04 V Precision 1 Size 2 Bytes V Meter Value 1 0x09 V Meter Value 2 ...

Page 5: ...p1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 the PAN15 will report its Accumulated Power Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of c...

Page 6: ...uence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN15 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via th...

Page 7: ...erence Statement FCC Interference Statement FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no...

Page 8: ...8 ...

Reviews: