PAN11-4/-5  

Smart energy plug in switch

P

      

This   plug-in   ON/OFF   switch   PAN11   is   a   wireless   switch,   based   on   Z-Wave

technology.   Z-Wave

TM

  enabled devices displaying the Z-Wave

TM

  logo can also be

used   with   it   regardless   of   the   manufacturer,   and   can   also   be   used   in   other

manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of the connected

load   is   possible   with   other   manufacturer’s   wireless   Controller.   Each   switch   is

designed to act as a repeater.  Repeaters will re-transmit the RF signal to ensure that

the   signal   is   received   by   its   intended   destination   by   routing   the   signal   around

obstacles and radio dead spots. 

This   plug-in   ON/OFF   switch   is   able   to   detect   current   wattage   (

5~1500W

)   and

overload wattage (

1550~1700W

) of connected lights or appliances. When detecting

overload state, the Switch will be disabled and its On/Off button will be lockout of

which LED will flash quickly.  However, unplug and re-connect the switch will reset its

overload condition to normal status.

Adding to Z-Wave

TM

 Network

In the front casing, there is an On/Off button with LED indicator which is used to

toggle switch on and off or carry out inclusion, exclusion, reset or association. When

first power is applied, its LED flashes on and off alternately and repeatedly at 2-

second intervals. It implies that it has not been assigned a node ID and cannot work

with Z-Wave enabled devices. 

Auto Inclusion

The function of auto inclusion will be executed as long as the switch does not have

Node ID and just plug the switch into a wall outlet.

Note:

 Auto inclusion timeout is 4 minute during which the node information of 

explorer frame will be emitted once every 5 seconds.  Unlike “inclusion” function as 

shown in the table below, the execution of auto inclusion is free from pressing the 

On/Off button on the Switch.

The table below lists an operation summary of basic Z-Wave functions. Please refer 

to the instructions for your Z-WaveTM Certificated Primary Controller to access the 

Setup function, and to include/exclude/associate devices

1

Summary of Contents for PAN11-4

Page 1: ... connect the switch will reset its overload condition to normal status Adding to Z WaveTM Network In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 2 second intervals It implies that it has not been assig...

Page 2: ...three times within 1 5 seconds will enter Press On for on Press Off for off association mode 2 There are only one group for the switch Including a node ID allocated by Z Wave Controller means inclusion Excluding a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mo...

Page 3: ...tton The LED will turn ON and the load plugged into the Switch will also turn ON 5 To manually turn OFF the Switch simply press and release the On Off button The LED will turn OFF and the load plugged into the Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET ...

Page 4: ...o Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT_COMMAND 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the nodes of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0...

Page 5: ... Value 2 W Meter Value 3 W Meter Value 4 W LSB Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 2 2 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Rate Type 0x01 Meter Type 0x...

Page 6: ...t Command Command Class Meter Meter Get Scale 0x04 V Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 V Size 2 Bytes Meter Value Meter Value 1 High Byte V Meter Value 2 Low Byte V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will...

Page 7: ...nd to the node Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 PF Size 1 Bytes Meter Value 1 Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave s Configuration 7 Meter Report Command Command Class Meter Meter Report scale bit 2 Rate Type Meter Type Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Meter Get Comm...

Page 8: ... the setting is configured for 1hour set value 6 the PAN11 will report its Accumulated Power Consumption KW h every 1 hour to Z Wave Controller The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 4 Command Classes The Switch supports Command Classes including COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_BASIC COMMAND_CLASS_MANUFACTURER_SPE...

Page 9: ... working and LED off 1 The Switch is not plugged into the electrical outlet properly 2 The Switch break down 1 Check power connections 2 Don t open up the Switch and send it for repair The Switch LED illuminating but cannot control the ON OFF Switch of the load attached Check if the load plugged into the Switch has its own ON OFF switch Set the ON OFF switch of the load attached to ON The Switch L...

Page 10: ...collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B...

Page 11: ...peration is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must n...

Reviews: