When PAN34 detect Overload, it will send Notification Report to Group1, Notification 

_Type = 0x08, Notification State = 0x08. When it receive Notification Get command 

with Notification Type = 0x08 and the PAN34 not in overload status, it will send Notifi-

cation Report, Notification Type = 0x08, Notification State = 0x00.

When PAN34 detect an overload power, it will send Notification Report to Group1.  

[Command Class Notification, Notification Report, Notification Type = 0x08, 

Notification State = 0x08 (Overload)]

[Command Class Notification, Notification Report, Notification Type = 0x08,

Notification State = 0x00 (Normal)] 

5. Z-Wave’s Configuration

Configura

tion

Parameter

Function

Size

(Byte)

Value

Unit

Default

Description

1

Watt 

Meter 

Report  

Period

2

0x01-

0x7FFF

5s

720

0: Disable auto 

Report

1~0x7FFF:   5s   

~45 hour

2

External 

switch 

type

1

1-2

2

1: One Push button

2:Two Push button

3

Total  

moving 

time of  

curtain

2

0-6000

0.1

Second

0

0: The time depends 

on Moving Range 

Calibration

1~6000: 0.1s~600s

4

Watt 

1

1-5

Watt

1

The threshold is a 

threshold

judgment for motor 

running or not

5

Watt 

differential

1

0-1

1

0: It will not report 

Watt when change 

over 5%

1: It will report watt 

value when the 

differential is over 5%

6

Timer 

offset for 

motor 

start 

running

2

0-255

0.01

second

50

0-255: 0s ~ 2.55s

50 = 0.5s

5-1 Watt Meter Report Period:

If the setting is configured for 1hour (set value =720), the PAN34 will report its instant

power consumption every 1 hour to the node of Group 1. The maximum interval to 

report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default 

value is 1 hour.  If the setting value is 0, the auto report function of meter Watt will be 

disabled.

5-2 External switch type

5-2-1 One Push Button

 

When the configuration setting is One Push Button, only S1 input will be valid. 

The control moving commands can be accepted in this switch type while the 

shutter is moving. In this switch type, the inclusion/exclusion/reset function can 

also be fulfilled by pressing S1 just like the operation of include button.

10

Summary of Contents for PAN34

Page 1: ......

Page 2: ...Cause of Failure Recommendation The PAN34 not working and LED off 1 The PAN34 is not connect to the Main power 2 The PAN34 break down 1 Check power connections 2 Don t open up the PAN34 and send it for repair The shutter move direction is reverse Wrong connection of NC and NO to the motor Swap the NC NO connection PAN34 LED light work fine But can not control 1 No association setting 2 Same freque...

Page 3: ...of heat e g fires radiators boiler etc 4 After putting it into use the body of Module will become a little bit hot of which phenomenon is normal Adding to Z WaveTM Network In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset The table below lists an operation summary of basic Z Wave functions Please refer to the instructions f...

Page 4: ...erwise inoperable 2 Within 1 second press Include button again for 5 seconds 3 IDs are excluded LED 2s On 2s Off No node ID Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes people are not easy to execute exclusion o...

Page 5: ...4 will know the total range from the BOTTOM to the TOP 2 During the shutter calibration process any emergencies happen you can press and release the include button to stop the process 3 If user found the direction is reverse this may cause by the wrong connection of NC and NO to the motor please exchange NC and NO connection and execute calibration process again 4 For safe issue please select the ...

Page 6: ...h Multilevel Switch Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Set Value 0xFF 255 control the shutter to the the most recent non zero level Command Class Multilevel Switch Multilevel Switch Set Value 0x01 0x62 control the shutter to the position between Bottom and Top 2 2 MULTILEVEL SWITCH GET When PAN34 receive Multilevel Switch Get C...

Page 7: ...t you may using S1 or S2 move shutter to the end or remote move shutter to 0 and 100 and that will automatically calibrate this error 2 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN34 will stop the motor Z wave s Groups introduction Maximum 5 nodes There is only one group called Lifeline there is only 5 nodes for Group1 which sup port MULTILEV...

Page 8: ...Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 3 3 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x00 Size 4 Mete...

Page 9: ...ecision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 3 3 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 ...

Page 10: ...nd 0 0 The time depends on Moving Range Calibration 1 6000 0 1s 600s 4 Watt 1 1 5 Watt 1 The threshold is a threshold judgment for motor running or not 5 Watt differential 1 0 1 1 0 It will not report Watt when change over 5 1 It will report watt value when the differential is over 5 6 Timer offset for motor start running 2 0 255 0 01 second 50 0 255 0s 2 55s 50 0 5s 5 1 Watt Meter Report Period I...

Page 11: ...s moving short pressed S2 again the shutter just keeps moving down toward BOTTOM 0x00 The easy way to stop this moving is short pressing S1 When in Two Push Button switch type S1 or S2 are pressed and not released and PAN34 receive any control moving command from Z Wave RF Ex BASIC_SET MULTILEVEL_SWITCH_SET MULTILEVEL_SWITCH_START_L EVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE PAN34 won t do...

Page 12: ...o return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC Interference Statement This equipment has been tested and found to comply with the ...

Page 13: ...rence that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警 警 警 警語 語 語 語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更頻 率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及...

Reviews: