Phihong USA Corporation
•
East Coast Engineering Center
•
630 Johnson Ave. Suite 102, Bohemia, NY 11716
•
Tel: (631) 610-2289
www.Phihong.com
IP address, subnet mask, and Gateway
address.
Note
: If the user manually assigns the IP
address, the DHCP client must be set to
Disable.
Device ID
1
A 16-bit integer; ranging from 0 to 65535
Setup password
administrator
The login password can be empty or 1-15
characters long. Please write your new
password down in a safe location for future
use.
The Setup password is also use while
performing a SNMP Firmware update.
Disable
0.0.0.0
0.0.0.0
0.0.0.0
Access control
Accessible address
0.0.0.0
The default setting (Disable) sets the Access
control to allow all IP address access
capability. If the Access control is Enable,
only the IP addresses listed in the Accessible
addresses will be able to access the SNMP
commands.
Accessible address is the IP addresses that
are allowed to read and write SNMP
commands to the NIC Interface Midspan.
You can set the IP addresses in the Controller
Setup or HyperTerminal.
SNMP agent
Enable
Enable or Disable the SNMP agent.
Read community
public
Option to set public or private
Set Community
private
Option to set public or private
0.0.0.0
0.0.0.0
0.0.0.0
Trap hosts
0.0.0.0
Trap hosts are the destination IP addresses
that you want the Traps to be sent to. You
can set the IP addresses in the Controller
Setup or HyperTerminal.
NOTE:
Trap Notifications are blocked from entering through the Windows Firewall. Please
configure the Windows Firewall settings to allow incoming Network Connections, by adding a
specific program (i.e. the SNMP Console).
or
www.Midspans.com
33