![PHI VILLA E02GS037 Use And Care Manual Download Page 9](http://html1.mh-extra.com/html/phi-villa/e02gs037/e02gs037_use-and-care-manual_1537013009.webp)
Cylinder/Gas line connection
Lighting
Figure 7
1. Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three parts water.
2. Make sure regulator/control knob is in the “OFF” position as shown (See Figure 7).
3. Apply the leak detection check solution on the “X” location as shown (See Figure 6).
a. If any bubbles appear, remove the propane cylinder and reconnect, make sure the connection is secure.
b. If you continue to see bubbles after several attempts, remove the propane cylinder per “Disconnect Propane Cylinder” section
and contact us for assistance.
c. If no bubbles appear after one minute,turn regulator/control knob to the “ OFF” position, wipe away solution and proceed.
1. Make sure all packagings have been removed from the outdoor firepit.
2. Check for obstructions of airflow to the burner Spiders, insects and webs can clog the burner/venturi tube. A clogged burner tube
can lead to a fire.
3. Control knob must be in the “OFF” position.
4. Clear small area of glass beads away from the igniter cover.
5. Connect propane cylinder per “Connecting Propane Cylinder” section.
CAUTION
DO NOT obstruct the flow of combustion and ventilation air.
CAUTION
Keep outdoor gas appliance area clear and free from combustible materials, gasoline and other flammable vapors
and liquids.
CAUTION
Check and clean burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire.
WARNING
NEVER light the burner with a cover on the outdoor firepit.
WARNING
Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause
death, serious bodily injury or damage to property.
OPERATION INSTRUCTIONS
9