PHI VILLA E02GS010 Use And Care Manual Download Page 12

     WARNING: 

If the information in this manual is not followed exactly, a fire or explosion may result causing 

property damage, personal injury, or loss of life.

Model No:  

Serial No:        

DANGER

CARBON MONOXIDE 

HAZARD

This appliance can 
produce carbon 
monoxide which has no 
odor. Using it in an 
enclosed space can kill 
you. Never use this
appliance in an enclosed
space such as a camper, 
tent, car or home.     

WARNING:

     

WARNING: 

 Placing the cylinder too close to the appliance might cause the fire hazard or property loss or 

even life hazard.

Type of gas: propane
Normal hourly input: 50,000BTU/hr (14.65 kW)
Manifold pressure: 11 inch w.c. (2.74 kPa)
Maximum inlet supply pressure: 250 psi

     CAUTION: 

The gas pressure regulator provided with this appliance must be used. 

This regulator is set for an outlet pressure of 11 inches water column.

 

Minimum Clearance From Unit To Combustible Construction: 72” (182.9cm) from the top, 
24” (61cm) from all sides and back.
For Outdoor Use Only. If Stored Indoors, Detach and Leave Cylinder Outdoors.
The gas supply must be turned off at the LP-gas supply cylinder when this appliance is not in use.

Complies with ANS Z21.97-2017   CSA 2.41-2017, Outdoor Decorative Gas Appliance Standards.
Cover must be removed when burner is in operation.
Removal of this marking will void compliance with standard ANS Z21.97-2017   CSA 2.41-2017.
Do not connect to a remote gas supply.

 

The instruction manual contains important information necessary for the proper assembly and safe use of the appliance.
Read and follow all warnings and instructions before assembling and using the appliance.
Follow all warnings and instructions when using the appliance.
If instructions or parts are missing. please email us at [email protected]

.

NECTAR INTL CO LTD
FLAT C,23/F,LUCKY PLAZA,
315-321 LOCKHART ROAD
WAN CHAI,HONG KONG

Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of this or any other appliance. 
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

     

WARNING:

 Improper 

installation, adjustment, 
alteration, service or 
maintenance can cause 
property damage, personal 
injury or loss life. Refer to 
the owner's information 
manual provided with this 
appliance. Installation and 
service must be performed 
by a qulified installer, 
service agency, or the gas 
supplier.

      CAUTION: 

This appliance has been converted to use natural gas. Propane orifice dia 2.21 mm, 

natural gas orifice dia 4.18 mm. 
Rated Heat Input: 50,000BTU/hr (14.65 kW). 
Type Gas: Natural gas
Manifold Pressure: 7 inches water column (1.74 kPa).

This appliance was converted on                            (day-month-year) to                
(insert gas type; e.g. Natural or Propane) gas with Kit. No.                    by                            
(name and address of organization making this conversion), which accepts the responsibility that this 
conversion has been properly made.

Figure 17

conversion label

propane rating plate

Figure 15

Figure 16

5. Stick and cover the conversion label onto the propane rating plate (see Figure 17).

gas valve

natural gas hose

natural gas fixture

natural gas supply system

 

 

4. Connect the natural gas hose to the gas valve by screwing clockwise tightly (see Figure 15). Plug the natural gas fixture into the 

natural gas supply system (see Figure 16). The conversion kit should be CSA certified. Below are several suggested CSA certified  

conversion kits for your reference. 

(1). Part# DH22 / QH1, manufacturer: KSUN 

or (2). Part# WH02 / KJ50A2, manufacturer: Laite 

or (3). Part# KJ-3/8G-3/8  / KJ-3/8G, manufacturer: Wanan

The natural gas orifice is included in the package. Please follow the instructions for gas conversion.

12

NATURAL GAS CONVERSION

WARNING:

This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s intructions and all applicable codes and requirements of the Authority Having 
Jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or 
production of carbon monoxide may result causing property damage, personal injury or loss of life. 
The qualified service agency is responsible for the proper installation of this kit. The installation is 
not proper and complete until the operation of the converted appliance is checked as specified in the 
manufacturer’s instructions supplied with the kit.

LIFE GETS BETTER WITH PHI VILLA

Summary of Contents for E02GS010

Page 1: ...ease contact our Customer Service service alphamarts com We appreciate the trust and con dence you have placed in PHI VILLA through the purchase of our product We strive to continually create quality...

Page 2: ...s not followed exactly a re or explosion may result causing property damage personal injury or loss of life INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future refere...

Page 3: ...ulating air passageways of the appliance are kept clean CAUTION The propane gas pressure regulator provided with this appliance must be used This regulator is set for an outlet pressure of 11 inches w...

Page 4: ...sed space When this appliance is not in use the gas must be turned off at the supply cylinder Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed from the...

Page 5: ...right leg H 1 pc Front left leg I 1 pc Back left leg J 1 pc Back right leg K 1 pc Gas cylinder support Lid Table top assembly PART DESCRIPTION QUANTITY L 2 pack M 1 pc Q 16 pcs Bolt M6 x 12 Natural g...

Page 6: ...t leg J and front left leg H and front right leg G to table top assembly B with bolts AA and washer CC by using hex screw driver DD see Figure 2 3 Attach front panel C to front left leg H and front ri...

Page 7: ...E to back left leg I and back right leg J with bolts AA and washer CC using hex screw driver DD see Figure 5 ASSEMBLY INSTRUCTIONS Hardware Used AA Bolts M6 x 15 x 4 CC Washer M6 x 4 DD Hex screw driv...

Page 8: ...with the bolt EE using a Phillips screwdriver NOT included see Figure 8 7 With the help of another person carefully turn the re pit to the upright position Attach the door panel D to the back left le...

Page 9: ...potentially be a projectile These hot pieces could cause injury or property damage As a precaution please follow these instructions the rst time the re pit is used 1 On rst use do not stand over or n...

Page 10: ...cylinder support K see Figure 10 so that the gas cylinder cannot move from side to side or fall down The knob on the control panel is turned all the way to the OFF position when the re pit in NOT in u...

Page 11: ...gas orifice gas valve propane hose 2 Unscrew and disconnect the propane ori ce from the bellows see Figure 13 Propane ori ce 2 21 mm diameter size is painted with red mark 3 Replace the propane ori ce...

Page 12: ...RNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss life Refer to the owner s information manual provided with this appliance Ins...

Page 13: ...resionando el bot n de encendido durante 15 segundos volver a su posici n hacia afuera Espere 5 minutos antes de intentar posici n APG apagado Battery Leak test WARNING 1 Please observe proper polarit...

Page 14: ...he connection has the leak disconnect the regulator reconnect perform another leak check If you continue to see bubbles after several attempts cylinder valve is defective and should be returned to cyl...

Page 15: ...ains on the product quickly 3 Dry the product with a soft cloth or paper towel 4 Do not use sharp tools to scratch the product 5 While cleaning the re pit make sure to keep the area around the burner...

Page 16: ...ns problems missing parts Before returning to the store please contact our Customer Service service alphamarts com Firepits Burner steel re pit bowl all mechanical parts and ttings to control panel an...

Reviews: