Page 1: ...AC DC KILOVOLTMETER MODEL NO KVM50A SERIAL NUMBER Phenix Technologies Inc 75 Speicher Drive Accident Maryland 21520 Copyright Phenix Technologies Inc DMC 2 2020 Rev New...

Page 2: ...SET UP 3 ELECTRICAL SET UP OPERATIONAL NOTES 4 OPERATING INSTRUCTIONS 5 CALIBRATION 6 MECHANICAL MAINTENANCE 7 STORAGE OF EQUIPMENT 8 TROUBLESHOOTING 9 PARTS LISTS 10 RECOMMENDED SPARE PARTS 11 PARTS...

Page 3: ...1 1 DANGER WARNINGS Complete Grounding of this unit is necessary for the safe operation of this equipment Disconnect inputs before ungrounding this equipment...

Page 4: ...st Equipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized and locked out...

Page 5: ...GES Low Range 20kV AC DC High Range 50kV AC DC ACCURACY 1 of Reading from 10 100 of Range FUNCTION SELECTIONS 1 Peak 2 Peak responding calibrated to RMS Value 2 Peak Peak responding calibrated to Peak...

Page 6: ...2 2 DIMENSIONS 30 H X 9 W X 91 2 D 775mm H X 241 mm W X 241 mm D WEIGHT 30 5 LBS 13 8 kg WEIGHT INCLUDES ALL CABLES...

Page 7: ...ermine if the unit was damaged in shipment If there are any signs of physical damage such as dents scratches or oil leaks contact the Service Department at Phenix Technologies before proceeding Read a...

Page 8: ...rt of the calibration Significantly changing the length of the meter lead will affect the AC calibration CAUTION The meter module has to be grounded for safe and proper operation Connect the ground po...

Page 9: ...ovides for battery charging or AC operation with included power adapter 5 GROUND STUD Ground stud for connected metering module to ground 6 BNC INPUT CONNECTOR BNC input connector connects the meterin...

Page 10: ...t will not over range on the AVG or the DC modes before attempting to read the ripple voltages DO NOT attempt to read ripple voltage on a range lower than required to measure the full input voltage Ac...

Page 11: ...gs will correspond to the type of meter used AVG will show AVG RMS will show RMS etc Use DC range for DC signals 10 meg input meter Select desired mode for voltmeter Activate high voltage source Measu...

Page 12: ...SHOULD ONLY BE DONE BY PERSONS FAMILIAR WITH HIGH VOLTAGE TESTING AND SAFETY PROCEDURES CALIBRATION PROCEDURES Due to the complexity and the standards required to calibrate this instrument Phenix Tec...

Page 13: ...nts in normal use It is recommended that the finish be wiped down with nothing stronger than ordinary household cleaner for longer life and for proper electrical operation of the unit Also inspect all...

Page 14: ...ged period the following precautions are recommended The equipment should be covered and kept in a warm dry environment 95 maximum humidity 5 to 50 degrees C Prior to placing the equipment back into o...

Page 15: ...ry may be discharged Recharge battery Unit blanked out during testing because of transient discharge occurrence and won t come back on by cycling the power switch Carefully remove front panel and unpl...

Page 16: ...1372P1 BATTERY POWER MANAGER 1 PCB 1405P0 KVM INTERFACE BRD 1 PCB 1417P1 METERING BRD 1 PWR ADAPT 15VDC SW POWER SUPPLY 2 1MM 1 PWR CABLE 1077167 INPUT POWER CABLE DIVIDER BASE 1 BNC 1153068 31 010 B...

Page 17: ...e unit will be operated at an isolated site for an extended period or will be subjected to unusual stresses a larger quantity of parts should be stocked as spares In such a case contact your Phenix Te...

Page 18: ...lude the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix Technologies will contact you to con...

Page 19: ...eason for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection arran...

Page 20: ...R M K K K TB X Intensite Diode Transisteur Thyristor Borne Ouvert Ferme Contact de SYMBOLE ZU SCHEMA SYMBOLES POUR SCHEMA DE CIRCUIT CIRCUIT DIAGRAM SYMBOLS Variable Resisitor Resistor Lamp Indicator...

Page 21: ...15 1 SECTION 15 SCHEMATICS AND DRAWINGS Drawing Number Description 1 7916005 KVM CONTROLS SCHEMATIC 2 796 XX XXXX KVM50EA SCHEMATIC...

Page 22: ......

Page 23: ...ual are correct If there are concerns or comments as you have used this information Phenix Technologies appreciates any feedback Unit Serial Number 18 2777 Sect Page s Comment Please return to Phenix...

Reviews: