SECTION 14:  CIRCUIT DIAGRAM SYMBOLS

 

 

 

 

 

Dispositif De Sur

Interrupteur Normalement

Interrupteur Normalement

Maintenu Ouvert

Interrupteur Normalement

Maintenu Ferme

Ouvert Momentanement

Ferme Momentanement

Interrupteur Normalement

DESCRIPTION

Condensateur

Unite d'amplificateur

Relais, Contacteur

Transformateur

Condensateur electrol

Transformateur de 

Resistance Variable

Prise de Courant

Contact Normalement 

Contact Normalement

Changement

Insrument Analogue

Diode Zener

Cable blinde

T

Transformer

Device

Current Overload 

Momentary Switch

Normally Open

Momentary Switch

Normally Closed

Normally Closed

Maintained Switch

Maintained Switch

Normally Closed

Normally Open

Normally Open

Thyristor

Zener

Diode

Analog Meter

Shielded Wire

Transistor

Changeover Contact

Relay Contact

Relay Contact

Connector

Terminal Block

DP

SW

SW

SW

SW

SCR

Z

D

TR

M

K

K

K

TB

X

Intensite

Diode

Transisteur

Thyristor

Borne

Ouvert

Ferme

Contact de 

SYMBOLE ZU SCHEMA

SYMBOLES POUR SCHEMA DE CIRCUIT

CIRCUIT DIAGRAM SYMBOLS

Variable Resisitor

Resistor

Lamp, Indicator

Neon

Movistor

Motor

Inductor

Relay, Contactor

Circuit Breaker

Current Transfomer

Fuse

Electrolytic Capacitor

Bushing

Capacitor

Surge Arrestor

Amplifier

BSHG

LP

R

R

NE

MOV

MOT

CB

K

L

CT

F

C

SYMBOL

ARSR

C

REF

A

Tranversee

Parafoudre

Moteur

Parafoudre

Lampe

Resistance

Courant

Fusible

Interupteur

Self

DESCRIPTION

Parafoudre

Transformer

Oeffnungskontakt

Abgeschirmetes Kabel

UeberstromschutzEinheit

Schrittschalter

Druckschalter

(Schliesser)

Schrittshalter

(Oeffner)

(Schliesser)

(Oeffner)

Druckschalter

Analog Meter

Transistor

Thyristor

Diode

Zener

Losbare Klemme

Steckverbindung

Schlierskontakt

Umschaltkontakt

BEMENKUNG

Ueberspannungsableiter

Ueberspannungsableiter

Eleckrolytik kondensator

Stromtransformer

Durchfuehoung

Widerstand

Movistor

Meldeleuchte

Widerstand

Motor

Sicherung

Drossel, Spule

Relais, Schutz

Unterbrecher

Kondensator

Verstarker

Summary of Contents for KVM 100A

Page 1: ...NUAL AC DC KILO VOLTMETER Model Number KVM 100A 200A PHENIX TECHNOLOGIES INC 75 Speicher Drive Accident MD 21520 Phone 1 301 746 8118 Fax 1 301 895 5570 E mail info phenixtech com Copyright Phenix Tec...

Page 2: ...NICAL SET UP 3 ELECTRICAL SET UP OPERATIONAL NOTES 4 OPERATING INSTRUCTIONS 5 CALIBRATION 6 MECHANICAL MAINTENANCE 7 STORAGE OF EQUIPMENT 8 TROUBLESHOOTING 9 PARTS LISTS 10 RECOMMENDED SPARE PARTS 11...

Page 3: ...KVM100A 200A 1 1 DANGER WARNINGS Complete Grounding of this unit is necessary for the safe operation of this equipment Disconnect inputs before ungrounding this equipment...

Page 4: ...ed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized and locked out Never work alone always wo...

Page 5: ...Range FUNCTION SELECTIONS 1 AC AVERAGE Average absolute value not RMS equivalent 2 AC RMS True AC RMS 3 AC PEAK Average of the positive and negative peak values 4 AC PEAK 2 AC PEAK 2 5 DC AVERAGE Ave...

Page 6: ...to determine if the unit was damaged in shipment If there are any signs of physical damage such as dents scratches or oil leaks contact the Service Department at Phenix Technologies before proceeding...

Page 7: ...ter divider from above at an angle of no greater than forty five degrees from vertical for highest accuracy readings CAUTION Metering module and divider base must be grounded for safe and proper opera...

Page 8: ...KVM100A 200A 4 2 ELECTRICAL SET UP OPERATIONAL NOTES Figure 1 KVM Testing Setup...

Page 9: ...ttery charging or AC operation with included power adapter 5 GROUND STUD Ground stud for connecting metering module to source ground 6 BNC INPUT CONNECTOR BNC connector to connect the metering module...

Page 10: ...it will not over range on the AVG or the DC modes before attempting to read the ripple voltages DO NOT attempt to read ripple voltage on a range lower than required to measure the full input voltage 5...

Page 11: ...eadings will correspond to the type of meter used AVG will show AVG RMS will show RMS etc Use DC range for DC signals 10 meg input meter 3 Select desired mode for voltmeter 4 Activate high voltage sou...

Page 12: ...S It is recommended calibration be performed on yearly basis Due to the complexity and the standards required to calibrate this instrument Phenix Technologies does not recommend customer calibration F...

Page 13: ...t the elements in normal use It is recommended that finish be wiped down with nothing stronger than ordinary household cleaner for longer life and for proper electrical operation of the unit Also insp...

Page 14: ...r a prolonged period the following precautions are recommended Equipment should be covered and kept in warm dry environment 95 maximum humidity 5 to 50 degrees C Prior to placing equipment back into o...

Page 15: ...n Battery may be discharged Recharge battery Unit blanked out during testing because of transient discharge occurrence and won t come back on by cycling the power switch Carefully remove front panel a...

Page 16: ...D PANEL 1 NE1 1609990 NEON LAMP 1 PCB 1372 31137200 BATTERY POWER MANAGER 1 PCB 1405 31140500 INTERFACE BRD 1 PCB 1417 31141700 METERING BRD 1 PS1 1590050 POWER SUPPLY 1 PS1 1077167 POWER CABLE DIVIDE...

Page 17: ...ormal operation If the unit will be operated at an isolated site for an extended period or will be subjected to unusual stresses a larger quantity of parts should be stocked as spares In such a case c...

Page 18: ...to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix Technologies will contact you...

Page 19: ...umber Reason for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspectio...

Page 20: ...Z D TR M K K K TB X Intensite Diode Transisteur Thyristor Borne Ouvert Ferme Contact de SYMBOLE ZU SCHEMA SYMBOLES POUR SCHEMA DE CIRCUIT CIRCUIT DIAGRAM SYMBOLS Variable Resisitor Resistor Lamp Indi...

Page 21: ...KVM100A 200A 15 1 SECTION 15 SCHEMATICS AND DRAWINGS Drawing Number Description 1 7916005 KVM100A 200A SCHEMATIC...

Page 22: ...KVM100A 200A...

Page 23: ...rator s Manual are correct If there are concerns or comments as you have used this information Phenix Technologies appreciates any feedback Unit Serial Number Sect Page s Comment Please return to Phen...

Reviews: