background image

SAFETY PRECAUTIONS

Please read all instructions before attempting to unpack, install or 

operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this 

equipment:
• 

Always follow basic safety precautions to reduce the risk of fi re, 

electrical shock and injury to persons.

• 

To prevent fi re or shock hazard, do not expose the unit to rain, 

moisture or install this product near water.

•  Never spill liquid of any kind on or into this product.
•  Never push an object of any kind into this product through any  

openings or empty slots in the unit, as you may damage parts 

inside the unit.

•  Do not attach the power supply cabling to building surfaces.
•  Use only the supplied power supply unit (PSU). Do not use the PSU 

if it is damaged.

•  Do not allow anything to rest on the power cabling or allow any 

weight to be placed upon it or any person walk on it.

•  To protect the unit from overheating, do not block any vents or 

openings in the unit housing that provide ventilation and allow for 

suffi cient space for air to circulate around the unit.

REVISION HISTORY

VERSION NO.

DATE DD/MM/YY

SUMMARY OF CHANGE

VR0

10/02/14

Preliminary Release

PhD Solutions Product Warranty 

Should you feel your product does not function adequately due to defects in materials or 

workmanship, PhD Solutions   

(hereby referred to as “the warrantor”) will, for the length of the period 

indicated below: 

a)     Repair the product with new or refurbished parts. 

or 

b)    Replace it with a new or refurbished product. 

 

Limited Warranty Period 

Commencing from the original date of purchase, all PhD Solutions products are covered by a 

one 

year PARTS

 and 

LABOUR 

warranty depending on the product

.

 

Please contact your PhD Solutions dealer for details. 

During this period there will be no charge for unit repair, replacement of parts, unit components or 

replacement of product if necessary. The decision to repair or replace will be made by the warrantor. 

The purchaser must mail-in or return the product to PhD Solutions during the warranty period. 

This limited warranty only covers the product purchased as new and is extended to the original 

purchaser only. It is non-transferable to subsequent owners, even during the warranty period. 

A purchase receipt or other proof of original purchase date is required for the limited warranty service. 

IF REPAIR IS NEEDED DURING THE LIMITED WARRANTY PERIOD THE PURCHASER WILL BE 

REQUIRED TO PRODUCE A SALES RECEIPT/PROOF OF PURCHASE INDICATING DATE OF 

PURCHASE, AMOUNT PAID AND PLACE OF PURCHASE. 

Please note: THE CUSTOMER WILL BE CHARGED FOR PARTS OR REPAIR OF 
ANY UNIT RECEIVED WITHOUT SUCH PROOF OF PURCHASE. 

Product Service Provided

 

1. Damage requiring service 

All units should be serviced by a PhD Solutions qualified service person.: 

2. Servicing Personnel 

Do not attempt to service the unit beyond that described in these operating instructions. Refer all 

other servicing to authorised PhD Solutions servicing personnel. 

 

9

Summary of Contents for EXC-P507HDRXE

Page 1: ...CH 507TX RX HDMI to CAT5e 6 with LAN IR RS 232 Operation Manual Operation Manual EXC P507HDTX RXE...

Page 2: ...gs or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it i...

Page 3: ...age Contents 1 4 System Requirements 1 5 Features 2 6 Operation Controls and Functions 3 6 1 Transmitter Front and Rear Panels 3 6 2 Receiver Front and Rear Panels 4 6 3 D Sub 9 Pin De nitions 5 7 Con...

Page 4: ...APPLICATIONS Household entertainment sharing and control Lecture room display and control Showroom display and control Meeting room presentation and control Classroom display and control 3 PACKAGE CON...

Page 5: ...it Audio support up to 7 1CH Dolby TrueHD DTS HD 5Play convergence HDMI LAN PoE Control IR RS 232 Installation Friendly Note 1 This system was tested with CAT6 23AWG cables results may vary with cable...

Page 6: ...will illuminate when the device is connected to a power supply 5 DC 24V Plug the 24V DC power supply into the unit and connect the adaptor to an AC outlet 6 IR 1 Blaster Connect to the supplied IR bl...

Page 7: ...S 232 commands 4 Power LED This blue LED will illuminate when the device is connected to a power supply 5 IR 2 Blaster Connect to the supplied IR blaster cable for IR signal transmission Place the IR...

Page 8: ...e Pin Assignment 3 1 2 3 1 2 Power 5V IR Blaster Signal NC IR Signal Power 5V Grounding IR Receiver IR Blaster 6 4 D Sub 9 Pin De nitions Pin De ne TX RX 1 N C 2 TxD RxD 3 RxD TxD 4 N C 5 GND 6 N C 7...

Page 9: ...In Link IR1 Extender IR2 Blaster Power RS 232 Out LAN HDMI Out CAT5e 6 to HDMI with LAN IR RS232 Receiver 1 5m 60 1 5m 60 7m 3m 3m 60 7m 3m 3m 60 RS 232 Equipped PC or Notebook RS 232 Equipped HDMI S...

Page 10: ...0 Meters HDMI In Out Supports Resolution 480i 1080p 50 60 1080p 24 VGA WUXGA IR Frequency 30 50kHz ESD Protection Human Body Model 8kV air gap discharge 4kV contact discharge Power Supply 24V 1 25A DC...

Page 11: ...COMPLETE TERM CAT5e Category 5 Cable CAT6 Category 6 Cable CEC Consumer Electronics Control DVI Digital Visual Interface HDCP High bandwidth Digital Content Protection HDMI High De nition Multimedia...

Page 12: ...il in or return the product to PhD Solutions during the warranty period This limited warranty only covers the product purchased as new and is extended to the original purchaser only It is non transfer...

Page 13: ...T COVER damage that occurs in shipment or failures caused by products not supplied by the warrantor Failures resulting from accident misuse abuse neglect mishandling misapplication alteration incorrec...

Page 14: ...Premium High Definition Solutions Home page http www phdsolutions co...