SEQUENCE SELECT BUTTON 

SEQUENCE 

BEEPER RESPONSE 

Apx Q, 1 minute  
Apx Q, 2 Minute 
Apx Q, 3 Minute 

A

px Q, Recall 

R

ule 26, 3 Minute 

R

ule 26, 5 minute 

Rule 26, Recall 
Matchrace

 

P

re-2001 2 minute 

P

re-2001 3 minute 

P

re-2001 5 minute

 

 

NOTE:

 See Sequence Selection page for details. 

QUICKSTART PROCEDURE 

• 

Plug RPS into 12 volt power source (ships battery, battery pack, etc) 
Verify that the beeper and horn chirp 

• 

Set 

Sequence Select

 for desired starting sequence. 

• 

Depress 

Sequence Start 

(You are now running a race) 

• 

See configuration page to change Cycle, Attention, or delay options. 

IMPORTANT 

• 

The horn needs a good electrical connection.  While it doesn’t use a lot of 
power, it does draw 

13 amperes

 for short periods.  If the ship’s wiring is 

light gauge, long, or corroded it can’t supply the power needed at the horn.  
Consider a direct wire run to the ships battery. 

MANUAL 
HORN

 

SHAPE 
ALERT  
SELECT

 

 

SEQUENCE 
SELECT 

SEQUENCE  
START

 

REGATTA PRO-START

 

RESET 

PHC 

   SYSTEMS 

www.phcsystems.com

 

Depress and release

 to determine the sequence you are 

in. 

Depress and hold 

to cycle through the sequences.  

Release

 when you are at the desired sequence

Depress and release

 to determine the seconds for shape 

alert. 

Depress and hold

 to cycle through the shape alert values 

Release

 when you are at the desired value. 

Depress and release

 to start the selected sequence. 

Depress

 at any time to sound the horn. 

Sequences in progress are 

not

 affected. 

Depress

 ‘Sequence Select’ and ‘Shape Alert Select’ 

together to reset any sequence in progress. 

SHAPE ALERT BUTTON 

Sets configuration options as follows:

 

SEQUENCE 

“SHAPE ALERT SELECT”  
FUNCTION 

Apx Q, 1 minute 
Apx Q, 2 Minute 
Apx Q, 3 Minute 
Apx Q, Recall 
 
Rule 26, 3 Minute 
Rule 26, 5 minute 
Rule 26, Recall 
 
Matchrace 
Pre-2001 2 minute 
Pre-2001 3 minute 
Pre-2001 5 minute 

 

 

Sets Apx Q

 cycle 

Sets Apx Q

 Attention 

Sets Apx Q

 delay 

 

Sets Rule 26

 cycle 

Sets Rule 26

 Attention 

Sets Rule 26

 delay 

 
Attention

 prior to warning 

Shape takedown

 prior to start 

Shape takedown

 prior to start 

Shape takedown

 prior to start 

 

NOTE: 

See Configuration page for details. 

 

 

  

 

  

  

−−

  

  

  

−−

  

 

  

  

  

  

−−

  

 

 

 

  

  

  

  

−−

 

  

  

  

  

−−

  

 

  

  

  

   

  

 

  

      

  

−−

 

  

   

−−

       

  

  

−−

 

  

  

  

  

−−

      

  

  

  

  

−−

 