Chapter 2: Installation
22
Phason
Supra interior layout
Voltage selection switch
–
set this switch to the correct voltage before installing the Supra.
Incoming power fuse
(F5)
–
1 A, 250 VAC non-time-delay glass fuse.
Variable stage fuses
(F1 to F4)
–
15 A, 250 VAC fast-acting ceramic. F1 is for variable stage 1, F2 for stage 2, and
so on.
Ground plate screw
–
connect a ground wire to this screw.
Variable stage terminals
(VAR1 to VAR4)
–
connect variable heating or cooling equipment such as fans or heat
lamps to these terminals.
General-purpose relay terminals
(RLY1 to RLY12)
–
connect single stage (on or off) equipment to these terminals.
You can configure these relays as heat, cool, duty cycle, timed event, curtain control, or inlet control.
Incoming power terminal
–
connect the incoming power (120/230 VAC, 50/60 Hz) to this terminal.