FC-1T-1F
1 / 4
10940000
FC-1T-1F user manual
The FC-1T-1F automatically controls the temperature in a room by switching fans, lamps, or heaters on or off as
the temperature drops below or exceeds the temperature set point.
When the SSC-1D is in cooling mode, it switches on the fans when the temperature exceeds the set point. When
the control is in heating mode, it switches on the lamps or heaters when the temperature drops below the set point.
Features
One solid-state relay
Heat and cool modes
Adjustable temperature set point,
32 to 99°F (0 to 37°C)
Fahrenheit and Celsius display
Six-foot temperature probe (extendable)
Error code display for troubleshooting
Overload protection fuse
Rugged, NEMA 4X enclosure (corrosion
resistant, water resistant, and fire retardant)
CSA approval
Two-year limited warranty
Installation
Switch OFF the power at the source before connecting the incoming power wires.
DO NOT switch on the power until you have finished all wiring and verified all equipment is
properly connected and free of obstructions.
Electrical ratings
Input:
120/230 VAC, 50/60 Hz
Relay:
10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
Fuse:
15 A, 250 VAC ABC-type ceramic
Temperature display units
Mode of operation