AutoFlex Connect Quick installation
32943005QS
Actuator Module
Each Actuator Module (model
ACT-1
) has one OPEN and one CLOSE relay for connecting actuators or curtain
machines. There is a connection for potentiometer feedback. For complete installation information, read
Connecting equipment to Actuator Modules
on page 14 of the
AutoFlex Connect installation guide
.
Curtain machines
AC powered actuators
DC powered actuators
Variable DC Module
Each Variable DC Module (model
VDC-4
) has four 0 to 10 V outputs for controlling variable frequency drives
(VFDs) or FanDRIVEs. For complete installation information, read
Connecting equipment to Variable DC Modules
on page 23 of the
AutoFlex Connect installation guide
.
The disconnect relay for the variable frequency drive is a relay on an RM-4 module. Configure the
relay to follow the variable DC output. For more information, refer to the online help at the AutoFlex
Connect display.
VFD start/stop connected
to a disconnect relay