Functions of the Phase II  PHT-2000 Hardness Tester 

Phase II PHT-2000 is an advanced, integrated hardness tester that provides high accuracy 
and simplicity of operation throughout a wide measuring range.  It is suitable for testing 
the hardness of ordinary metals and is widely applied in many industries including the 
petroleum, chemical, industrial machining and electric power industries, etc. 

 

2.1 Typical 

Applications 

Typical hardness testing applications of the PHT-2000 include: 

 

Inspection of installed machinery, permanent parts of assembled systems and heavy 
workpieces 

 

Inspection of the moulding surface of a die 

 

Analysis of pressure vessels, turbo generator sets, etc. 

 

Inspection of bearing and other mass produced parts on a production line 

 

Obtaining original records of test data 

 

2.2 Technical 

Data 

 

Display error 

±

0.8% at LD=900 

 

(Value display – Value actual x 100) 

  

Value 

Actual 

 

 

Relative repetitive display error 0.8% at LD=900 

 

(Value max – Value min. x 100) = Error 

  

Value 

Average 

 

 

2.3 Available 

Functions

 

 

Automatic identification of integrated impact device (D, DC, DL, D+15, C, G) 

 

Quick entry of a series of test numbers, test dates, sample material type and impact 
direction via the keypad. 

 

Deletion of erroneous or incorrect previously stored test data. 

 

Display of the current test mode and its corresponding test data. 

 

User selectable display of test data in any hardness value 

(

HL, HRC, HRB, HB, HV, HSD , 

δ

b) 

 

Low Battery Indicator 

 
 

2.4  Measuring and Converting Ranges 

Shown below are the impact devices, the corresponding measuring ranges for each (D, DC, DL,  
D+15, C, G) and their allowable conversion ranges in terms of other static hardness values 
(

HRC, HRB, HB, HV, HSD

) for different metals. 

 
 
 

 

 

Summary of Contents for PHT-2000

Page 1: ...struction Manual 201 933 6300 www phase2plus com Precision Measuring Tools Indexing Fixtures Workholding Fixtures Hardness Testers Ultrasonic Thickness Surface Finish Coating Thickness Model No PHT 20...

Page 2: ...production line Obtaining original records of test data 2 2 Technical Data Display error 0 8 at LD 900 Value display Value actual x 100 Value Actual Relative repetitive display error 0 8 at LD 900 Val...

Page 3: ...ength of 50mm It is suitable for testing in extremely confined spaces the base of grooves and on special components such as gear wheels For use on steel and cast steel only G Probe This device has an...

Page 4: ...40 173 Bronze 60 290 Copper 45 315 Table 3 Impact Device D 15 Measuring Range LD 15 300 900 Material HRC HRB HB HV HSD Steel Cast St 19 3 67 9 80 638 80 937 33 3 99 3 Table 4 Impact Device C Measuring...

Page 5: ...nst the sample surface by a spring force and then rebounds back At a distance of 1mm from the sample surface the impact and rebound velocity of the impact body are measured by the following method A p...

Page 6: ...15 Should be written as 22 8 HV LD 15 Where 22 hardness value HL 8 hardness value HV L Leeb s Method LD 15 impact device Hardness HRC converted from hardness L using impact device D should be written...

Page 7: ...nimum depth of hardened layer should be 0 03 in 0 8 mm The testing surface of the sample should be perpendicular to the impact direction Note The above restrictions referring to the rigidity of test s...

Page 8: ...button for 2 seconds 6 2 Setting of all Parameters Choosing an Impact Device Press the button to go to the main menu Use the button to scroll down to 6 D DC Press the button to scroll through the imp...

Page 9: ...ld the button a second time for 1 second to bring the backlight up to the second brightest stage Press and hold the button for a third time to aquire the brightest back light To turn off the back ligh...

Page 10: ...s will appear in memory 0001 and will continue to save test results in progressive order There is no need to change any settings Memory Recall While in the main test screen press the button to go to m...

Page 11: ...s with the axis of the impact device 6 4 Additional Features Alteration of parameters including hardness value and type of sample material can be performed during any measurement set The output result...

Page 12: ...ct body and support ring Release the impact spring after each test Never apply lubrication of any kind to impact body 7 2 Repair When the tester is calibrated against the Rockwell standard test block...

Page 13: ...0 0 0 Corrections to be added to Rockwell B F and G values Hardness Diameters of Convex Cylindrical Surfaces Reading 1 4 in 3 8 in 1 2 in 5 8 in 3 4 in 7 8 in 1 in 6 4 mm 10mm 13mm 16 mm 19 mm 22 mm 2...

Page 14: ...5 8 51 4 471 495 443 229 46 73 6 60 83 5 64 8 50 3 458 480 432 221 45 73 1 59 2 83 0 64 0 49 0 446 466 421 215 44 72 5 58 5 82 5 63 1 47 8 434 452 409 208 43 72 0 57 7 82 0 62 2 46 7 423 438 400 201 4...

Page 15: ...6 162 81 140 83 51 1 87 6 71 8 55 8 159 173 159 80 137 82 50 6 87 3 71 1 54 8 156 170 156 76 135 81 50 86 9 70 4 53 8 153 167 153 73 133 80 49 5 86 6 69 7 52 8 150 164 150 72 130 79 48 9 86 3 69 1 51...

Page 16: ...1 78 5 72 3 40 3 8 6 93 72 35 28 7 78 0 72 0 39 6 7 6 92 71 34 28 2 77 0 71 7 39 0 6 6 91 70 33 27 8 76 6 71 4 38 3 5 6 90 69 32 27 4 76 0 71 0 37 6 4 6 89 69 31 27 0 75 5 70 7 37 0 3 6 88 68 30 26 6...

Page 17: ...72 75 72 71 0 018 0 46 84 66 68 68 64 62 0 020 0 51 82 57 63 55 53 0 022 0 56 69 79 47 58 45 43 0 024 0 61 67 76 94 51 34 31 0 026 0 66 65 71 87 37 18 0 028 0 71 62 67 80 20 4 0 030 0 76 57 60 71 0 03...

Reviews: