First Time Operation With DMX:

• Before you start using this unit, please check there is no transportation damage, should there be any, please

do not use the device and contact your dealer immediately.

• The PFX900V is designed to be used with water based smoke, fog or vapour liquid.

• Put the smoke machine on a flat stable surface or truss mount following the instructions in this manual

carefully. Make sure no one can put any body part close to the heater output.

• Unscrew the Lid on the fluid bottle, fill up with a suitable fog liquid, do not to overfill. Screw the plastic cap

back on and ensure the tank never runs dry during operation.

• Connect a DMX controller to the DMX input socket. Terminate the output socket or connect to other DMX

fixtures. 

• Plug the mains plug into a suitable mains supply. Allow the unit to warm up for around 4 minutes

This unit uses 4 channels of DMX.

• Set a suitable DMX address via the digital display.

DMX Channel Layout:

Note: Channels 2, 3 and 4 connect be combined together, channel 3 has priority over 4 and channel 2 has

priority over 3 and 4.

Overhead Rigging:

The installation must be carried out by a qualified engineer only. Improper installation can result in injuries or

damage to property. Overhead rigging requires experience, working loads should be adhered to and certified

materials should be used. The installed device should be regularly inspected for safety.

• Make sure the working area is clear from people and obstructions during rigging, de rigging and servicing.

• Locate the smoke machine in a well ventilated area away from flammable materials and liquids. The smoke

machine needs to be 50cm away from surrounding walls and fixtures.

• The smoke machine should be installed out of reach of people and not where people are seated, walking or standing.

• When mounting make sure the installation point can take the weight.

• Make sure a safety chain or wire is always used and can take the weight of the smoke machine. The safety

bond should not be used as a primary support.

• The machine should be well fixed and free from swinging.

• Do not cover any ventilation holes.

• Disconnect the power when the machine is not in use.

• The operator must make sure the smoke machine has been installed correctly to all the necessary

guidelines before each use. The installation should be inspected every 6 months.

Channel:

Value:

Function:

1

000-005

NO fog output

006-255

FOG output ON

2

000-005

No Colour

006-085

RED

086-170

GREEN

171-255

BLUE

3

000-005

No Colour

006-085

RED + BLUE

086-170

GREEN + RED

171-255

BLUE + GREEN

4

000-005

No Colour

006-085

RANDOM Colour

Summary of Contents for Jet Blaster 900

Page 1: ...OT OPEN RISQUE D ELECTROCUTION NE PAS OUVRIR STROMSCHLAGGEFAHR NICHT OFFNEN In Compliance with the following directives RoHS Directive 2002 95 EU and WEEE directive 2002 96 EU If this product is no longer functional or reached the end of its usable life please take it to an approved recycling plant ...

Page 2: ...tside In the event of any liquid entering the housing unplug immediately contact a qualified engineer You must not attempt to modify this unit The manufacturer accepts no responsibility for injury or damage caused as a result of not following the manual provided Protection from Electric Shock Only connect this unit to a mains socket with suitable trip and RCD protection To disconnect from the main...

Page 3: ... water tanks before transporting Follow the cleaning and maintenance advice in this manual If your machine fails to work disconnect immediately remove all liquid and return in original packing to your dealer Danger of Injury or Burns For operation by adults only ensure installation is away from the reach of children Never leave the machine running unattended Avoid all contact with the heater Never...

Page 4: ... safety wire 4 DMX Input Female 3 pin to connect from a DMX controller or previous DMX fixture 5 DMX Output Male 3 pin to connect to next DMX fixture in the chain 6 Power Switch To turn the fogger on and off 7 Fuse Holder If this blows once replace if the correct size fuse if it blows again there may be a problem with the machine seek professional help from an engineer 8 Mains Lead Connect this to...

Page 5: ...o be used with water based fog or vapour liquid NEVER OIL BASED Put the smoke machine on a flat stable surface or hang from a suitable truss and use a safety wire as a secondary support Make sure no one can put any body part close to the heater output Unscrew the Lid on the fluid bottle fill up with a suitable fog liquid make sure not to over fil Then screw the plastic cap back on Make sure the ta...

Page 6: ...t in injuries or damage to property Overhead rigging requires experience working loads should be adhered to and certified materials should be used The installed device should be regularly inspected for safety Make sure the working area is clear from people and obstructions during rigging de rigging and servicing Locate the smoke machine in a well ventilated area away from flammable materials and l...

Page 7: ...safety chain or wire as a secondary support Maintenance Do not allow liquid to become contaminated Always replace the cap on the liquid container immediately after filling After every 40 hours of operation or if the unit is not to be used for one month It is recommended to run a cleaning solution of 20 clear vinegar and 80 distilled water through the system to prevent clogging in the heater This s...

Page 8: ...ntroller This is normally done by a digital display panel where the address can be changed by simple up and down buttons the address ranges from 1 512 Alternatively it may be controlled by a row of small switches called dip switches on this type system the required address is then converted to a binary number DMX Connector Wiring 3 Pin wiring is more common but the 5 pin configuration is often use...

Page 9: ...would be set to DMX address 11 Fixture 4 would be set to DMX address 16 When setting these addresses ensure that the fixture addresses dont overlap You can set two fixtures to the same address as long as they have the same channel layout they will then perform in the same way We recommend you to read manuals for your DMX fixture and controller in full Some controllers tell you what each fixture ad...