Operating requirements
10
14/09/2021
5 Operating requirements
Ambient conditions
Specification
Value Unit
Temperature range
2–45 °C
Relative humidity (maximum)
80 %
Operating period
Specification
Value Unit
Maximum continuous operating period
8 hours
6 Performance values
6.1 TWISTER D 6-3
Specification
Value Unit
Pumping capacity, approx.
7–23 l/min
Pumping capacity, approx.
14,5 l/min at 292 rpm
Max. operating pressure
30 bar
Pumping distance *, max. for 25 mm
30 m
Pumping distance *, max. for 35 mm
50 m
* Recommended value, depending on conveying height, condition and version of pump,
mortar quality (composition and consistency)
6.2 R
8-1,5
Angabe
Wert Einheit
Förderleistung bei FU-Maschine
ca. 15-50 l/min
Betriebsdruck, max.
15 bar
Förderweite *, max. bei 35 mm
30 m
* Richtwert bei Fließestrich je nach Förderhöhe, Pumpenzustand und - ausführung,
Materialqualität, - zusammensetzung und -konsistenz
7 Sound power level
Sound power level L
WA
78 dB (A)
8 Vibrations
Weighted effective acceleration value to which the upper limbs are exposed = < 2.5 m/s²