Place
Measures/safety equipment
Category 2
Category 3
Speci-
fica-
tion
We
rec-
om-
mend
Speci-
fica-
tion
We
rec-
om-
mend
Magnetic
coupling
First switch on the roots pump when the back-
ing pump can accept the required amount of
gas
x
x
You must observe the volume flow ratio of
≤ 10:1 between the roots pump and backing
pump
x
x
Only use the motors specified by Pfeiffer Vac-
uum.
x
x
Limitation of the motor torque by:
● frequency converter that limits the permis-
sible torque
or
● soft starter and continuous monitoring of
the power consumption
x
x
Piston
bearing
Check the power input of the motor to protect
against bearing damage on the roots pump
(see chapter “Checking the power in-
Or:
Regular vibration measurement at the defined
measuring points and required time intervals
x
x
Coaxiality
of the cen-
tering of
the flange
to the mo-
tor shaft
Check the coaxiality of the centering of the
flange to the shaft in accordance with standard
EN 50347: 2001, the table values reduced to
50 % are valid
Or:
Regular vibration measurement at the defined
measuring points and required time intervals
x
x
Gas outlet
tempera-
ture
Monitor the gas outlet temperature with the
and checking the temperature monitor-
.
x
x
Tbl. 6:
Measures and safety equipment
2.5 Limits of use of the product
Installation location
● Indoors, protected against:
─ dust deposits
─ falling objects
─ fire-fighting water
● Outdoors, protected against:
─ falling objects
─ direct influence of weather such as rain, splash
water, strong drafts and sunlight
─ fire-fighting water
─ lightning strike
Installation altitude
according to the motor used. Observe the motor manu-
facturer's operating instructions
Ambient temperature,
dependent on the pump design
+5°C to +40°C (for P3)
-20°C to +40°C (for H1)
Relative humidity of air
max. 85 % (depending on the motor version)
Orientation
Horizontal
Pumped medium intake temperature,
max.
process-specific
Permanent intake pressure in circulation
mode
< 1300 hPa (abs.)
Safety