background image

Dear Customer,

Thank you for choosing a Pfeiffer Vacuum product. Your new diaphragm pump is designed to 
support you with its performance, perfect operation and without impacting your individual 
application. The name Pfeiffer Vacuum stands for high-quality vacuum technology, a 
comprehensive and complete range of top-quality products and first-class service. From this 
extensive, practical experience we have gained a large volume of information that can 
contribute to efficient deployment and to your personal safety.
In the knowledge that our product must avoid consuming work output, we trust that our 
product can offer you a solution that supports you in the effective and trouble-free 
implementation of your individual application.
Please read these operating instructions before putting your product into operation for the 
first time. If you have any questions or suggestions, please feel free to contact 

info@pfeiffer-

vacuum.de

.

Further operating instructions from Pfeiffer Vacuum can be found in the 

Download Center

 on 

our website.

Disclaimer of liability

These operating instructions describe all models and variants of your product. Note that your 
product may not be equipped with all features described in this document. Pfeiffer Vacuum 
constantly adapts its products to the latest state of the art without prior notice. Please take 
into account that online operating instructions can deviate from the printed operating 
instructions supplied with your product.
Furthermore, Pfeiffer Vacuum assumes no responsibility or liability for damage resulting from 
the use of the product that contradicts its proper use or is explicitly defined as foreseeable 
misuse.

Copyright

This document is the intellectual property of Pfeiffer Vacuum and all contents of this 
document are protected by copyright. They may not be copied, altered, reproduced or 
published without the prior written permission of Pfeiffer Vacuum.
We reserve the right to make changes to the technical data and information in this document.

2/58

Summary of Contents for MVP 040-2

Page 1: ...OPERATING INSTRUCTIONS EN Translation of the Original MVP 040 2 MVP 070 3 MVP 070 3 C Diaphragm pump...

Page 2: ...act info pfeiffer vacuum de Further operating instructions from Pfeiffer Vacuum can be found in the Download Center on our website Disclaimer of liability These operating instructions describe all mod...

Page 3: ...Function 17 3 1 1 Drive 18 3 1 2 Pumping system 18 3 1 3 Cooling 18 3 1 4 Gas ballast 18 3 2 Connections 19 3 3 Identifying the product 19 3 4 Scope of delivery 19 4 Transportation and Storage 20 4 1...

Page 4: ...39 7 6 2 Removing diaphragms from MVP 070 3 C 40 7 6 3 Installing diaphragms for MVP 070 3 C 41 7 6 4 Installing vacuum pump MVP 070 3 C 42 7 7 Checking the final pressure 43 8 Decommissioning 44 9 R...

Page 5: ...use 29 Tbl 7 Maintenance intervals 30 Tbl 8 Troubleshooting on diaphragm pumps 47 Tbl 9 Spare parts packages 50 Tbl 10 Accessories MVP 040 2 51 Tbl 11 Accessories MVP 070 3 51 Tbl 12 Accessories MVP 0...

Page 6: ...itch 23 Fig 7 Gas ballast valve 27 Fig 8 Device fuses in terminal box 31 Fig 9 Individual parts MVP 040 2 33 Fig 10 Individual parts MVP 070 3 36 Fig 11 Function of diaphragm key 37 Fig 12 Individual...

Page 7: ...ersion MVP 070 3 as standard version MVP 070 3 C as corrosive gas version 1 2 Target group These operating instructions are aimed at all persons performing the following activities on the product Tran...

Page 8: ...w IP 40 Type 1 S N max 3 8 4 3 m h 100 115 V 50 60 Hz 5 7 A 120 V 60 Hz 4 0 A 200 230 V 50 60 Hz 3 0 A MVP 070 3 2021 07 PK T01 310 xxxxxxxxxx max 1800 1 min 16 4 kg 250W 3 2 UL CSA 61010 1 40 Rating...

Page 9: ...ter diam tre nominal ECTFE Ethylene chlortrifluorethylene ETFE Ethylene tetrafluoroethylene copolymer FFKM Perfluoroelastomer FPM Fluoropolymer rubber MVP Diaphragm vacuum pump MSL Mean sea level PA P...

Page 10: ...of damage to property Is used to highlight actions that are not associated with personal injury Instructions to avoid damage to property Notes tips or examples indicate important information about th...

Page 11: ...on the operating and ambient conditions the surface temperature of the vacuum pump can increase to above 70 C If access to the vacuum pump is unrestricted there is a danger of burns due to contact wit...

Page 12: ...ue to poisoning in processes with toxic process media If necessary use inert gas to avoid potential contamination If necessary use an extraction line CAUTION Danger of burns on hot surfaces Depending...

Page 13: ...ol down before carrying out any work Wear personal protective equipment if necessary Risks during disposal WARNING Health hazard through poisoning from toxic contaminated components or devices Toxic p...

Page 14: ...UL 50E NEMA type 1 Installation altitude max 2000 m above sea level 1 Ambient temperature 10 to 40 Relative humidity of air 85 at T 31 C to max 50 at T 40 C Degree of pollution 2 Overvoltage category...

Page 15: ...l work Only a trained specialist may carry out mechanical work Within the meaning of this document special ists are people responsible for construction mechanical installation troubleshooting and main...

Page 16: ...level 3 Customer with Pfeiffer Vacuum service training Pfeiffer Vacuum service technician 2 7 3 Advanced training with Pfeiffer Vacuum For optimal and trouble free use of this product Pfeiffer Vacuum...

Page 17: ...5 7 8 9 1 6 Fig 2 Design of vacuum pump MVP 040 2 1 Handle 7 Vacuum connection 2 Exhaust with silencer 8 Diaphragm head 1 3 Gas ballast valve 9 Mains switch 4 Interhead connection 10 Voltage selector...

Page 18: ...the thermic protection switch interrupts the motor current but does not offer a permanent shut down of the motor Once the motor has cooled down the vacuum pump restarts automatically 3 1 2 Pumping sys...

Page 19: ...cation of the product when communicating with Pfeiffer Vacuum always keep all of the information on the rating plate to hand Learn about certifications through test seals on the product or at www cert...

Page 20: ...ly sized level surface Transporting the vacuum pump without its packaging 1 Unpack the vacuum pump 2 To protect the inside of the pump leave both protective caps on the connections during transport 3...

Page 21: ...implementing the touch protection 1 Ensure easy access to mains plug at all times so that the vacuum pump can be disconnected from the supply voltage 2 Place the vacuum pump on a flat horizontal surf...

Page 22: ...aust gases and vapors freely into the air In processes involving toxic media there is a risk of injury and danger to life due to poisoning Observe the relevant regulations for handling toxic substance...

Page 23: ...unding for the device After connection work carry out an earthed conductor check NOTICE Risk of property damage from excess voltage Incorrect or excessive mains voltage will destroy the motor Always o...

Page 24: ...vacuum pump is installed or moved to a different location 2 Disconnect the vacuum pump from the mains 3 Set the required voltage range on the voltage selector switch using a suitable screwdriver Esta...

Page 25: ...1 bar differential pressure between inlet and outlet otherwise the motor jams and sus tains damage Make sure that the distributor is installed correctly on the diaphragm heads before connecting the v...

Page 26: ...use inert gas for supplying the flushing gas in order to avoid a potential ignition WARNING Risk of poisoning due to toxic process gases escaping For intake pressures 500 hPa process gas may escape f...

Page 27: ...led inlet of gas at the flushing gas nozzle leads to sparks generated mechanically following diaphragm rupture hot surfaces or to explosive gas air mixtures in the vacuum system caused by static elect...

Page 28: ...ng gas connection 4 Bring the vacuum pump to operating temperature before starting the process 5 Continue to operate the vacuum pump approx 30 minutes after finishing the process before switching it o...

Page 29: ...the vacuum pump for inspection away from the system if necessary NOTICE Damage caused by unsuitable cleaning agents Unsuitable cleaning agents damage pump parts Use only approved cleaning agents to cl...

Page 30: ...evel 2 We recommend that Pfeiffer Vacuum Service carry out maintenance work at level 2 If the specified intervals are exceeded or if maintenance work is carried out improperly no war ranty or liabilit...

Page 31: ...intentional re start The device fuses are located in the terminal box and are integrated in a cable Prerequisites Supply voltage switched off Drive motor disconnected from mains and secured against ac...

Page 32: ...vac uum or leads to bearing damage During disassembly keep the existing spacer disks separate per installation location Reinstall the same number of original spacer disks per diaphragm head Avoid inte...

Page 33: ...19 Housing panel 7 Compression coupling 20 Countersunk screws 8 Sealing rings 21 Head cover inlet side 9 Valves inlet and outlet 22 Housing cover inlet side 10 O rings 23 Valves made from PTFE white...

Page 34: ...for each installation location when mounting 5 Inspect diaphragm pair for damage 7 4 3 Installing diaphragms for MVP 040 2 Spare parts required Overhaul kit Required consumables Clean dry cloth Adhes...

Page 35: ...Tightening torque 12 0 Nm 7 Mount the hose connection 8 Prevent the hose fitting from turning using open end wrench WAF 20 9 Fit fitting with open end wrench WAF 17 7 5 Replacing diaphragms and valve...

Page 36: ...y voltage switched off Drive motor disconnected from mains and secured against activation Vacuum pump cooled Vacuum pump positioned on its side and supported as necessary Required tool Allen key WAF 5...

Page 37: ...ragm clamping disk diaphragm pair and diaphragm support disk 4 Apply alcohol or cleaning solvent to release diaphragm pair from supporting washer if it has be come stuck 5 Remove diaphragm pair and di...

Page 38: ...r 1 6 Procedure 1 Replace wear parts valves according to spare part package 2 Position diaphragms to sit centrally and flush on the supporting surface of the housing opening 3 Fit head cover on housin...

Page 39: ...Gas ballast valve 12 Head cover 3 Oval head screw for connection holder 13 Allen head screws 4 Connection holder with integral hinge and square nut 14 Diaphragm clamping disk 5 Valve cluster 15 Indivi...

Page 40: ...pposite side 8 Remove hose of hose connection 9 Unscrew countersunk screws on clamping claws 10 Remove clamping claws Head covers remain mounted 11 Completely remove valve clusters together with cup s...

Page 41: ...es Clean dry cloth Procedure 1 Clean all parts with a dry clean cloth 2 Replace wear parts diaphragms according to spare part package 3 Fit diaphragm with light side facing outward and diaphragm suppo...

Page 42: ...the pocket in the valve seat EX Outlet side The valve has the same orienta tion as the inlet valve Procedure 1 Replace wear parts valves according to spare part package 2 Insert valves and O rings 3 M...

Page 43: ...is reinserted 2 Compare the measured final pressure with the test values and the specifications in the technical data Prerequisites Vacuum pump mounted Vacuum pump correctly installed electrically Req...

Page 44: ...red the vacuum pump that may attack the pump materials or lead to deposits clean the inside of the pump heads Procedure for longer vacuum pump shutdowns 1 Disconnect the vacuum pump from the vacuum sy...

Page 45: ...nts must be disposed of in accordance with the applica ble regulations relating to environmental protection and human health with a view to reducing natural resource wastage and preventing pollution 9...

Page 46: ...fy the information on the nameplate Should malfunctions occur you can find information about potential causes and how to fix them here Problem Possible causes Remedy Vacuum pump will not start up No s...

Page 47: ...nections are short and cross sections ade quately dimensioned Exhaust pressure too high Check exhaust line outlet open ing and exhaust side accesso ries Unusual noises during opera tion Defective valv...

Page 48: ...ity You can find more detailed information and addresses on our homepage in the Pfeiffer Vacuum Service section You can obtain advice on the optimal solution for you from your Pfeiffer Vacuum represen...

Page 49: ...duct in suitable stable transport containers only e Maintain applicable transport conditions ERKL RUNG KONTAMINIERUNG 6 Attach the contamination declaration to the outside of the packag ing 7 Now send...

Page 50: ...r Remark MVP 040 2 MVP 070 3 MVP 070 3 C Overhaul kit PU E22 013 T PU E22 014 T PU E22 015 T Diaphragms valves O rings Silencer P 0920 412 E P 0920 412 E Usit sealing ring P 3529 143 C Sealing ring 1...

Page 51: ...0 2 Selection field Part number Relay box shielded for backing pumps 1 phase 7A for TC 110 120 and TCP 350 plug M8 PM 071 282 X Relay box shielded for backing pumps 1 phase 7 A for TC 400 1200 TM 700...

Page 52: ...92 7 5 9 87 sccm 1 69 10 2 1 69 10 3 1 1 27 10 2 1 67 10 2 Torr l s 1 33 0 133 78 9 1 1 32 atm cm3 s 1 01 0 101 59 8 0 76 1 Tbl 14 Conversion table Units for gas throughput 14 2 Technical data Type de...

Page 53: ...m h 4 3 m h 4 3 m h 4 3 m h 4 3 m h Gas ballast No No No No No Final pressure without gas ballast 1 hPa 1 hPa 1 hPa 1 hPa 1 hPa Final pressure with gas ballast Intake pressure max 1100 hPa 1100 hPa 1...

Page 54: ...ast 3 hPa 3 hPa Intake pressure max 1100 hPa 1100 hPa Exhaust pressure max 1100 hPa 1100 hPa Integral leakage rate 2 10 3 Pa m s 2 10 3 Pa m s Input voltage s 100 115 200 230 V AC 50 Hz 100 115 120 20...

Page 55: ...flange Stainless steel small flange PTFE strengthened with carbon hose nozzle Outlet PTFE carbon fiber rein forced Silencer PA PE aluminum PA PE aluminum Threaded hose couplings Anodized aluminum Ano...

Page 56: ...4 18 260 325 Fig 17 Dimensions MVP 070 3 Dimensions in mm Gasballast Gas ballast 108 IN Kleinflansch DN 16 Small flange DN 16 65 198 125 242 EX Schlauchwelle DN 10 Hose nozzle DN 10 51 18 260 325 Fig...

Page 57: ...65 EU Restriction of the use of certain hazardous substances delegated directive 2015 863 EU Harmonized standards and applied national standards and specifications DIN EN ISO 12100 2011 DIN EN IEC 630...

Page 58: ...PU0050 ed H Date 2108 P N PU0050BEN...

Reviews: