Establishing a connection for the trimmer
1. Make sure that no control signal is connected at the terminals of terminal block ST1B.
2. Connect the supply voltage at the corresponding terminals of terminal block ST1A.
5.4.2 Establishing a connection for interval operation
Required cables (accessories)
● Control cable, TC 110/120 - Diaphragm pump, 0.5 m
● Connection cable TPS - MVP
3
In +
+
In -
GND
nc
TC 110
24 V DC ext.
TPS
MVP
4
+
-
1
2
1
2
Fig. 5:
Connection to TC and TPS
Procedure
1. Establish the voltage supply.
2. Establish the control signal connection.
5.5 Connecting the voltage supply
NOTICE
Property damage due to incorrect polarity
Incorrect or excessive supply voltage will destroy the motor.
► Always observe the motor rating plate specifications.
► When connecting the supply cable, observe the colored marking on the corresponding wires.
► Always provide a suitable mains fuse.
NOTICE
Property damage from electrostatic discharge
Neglecting the electrostatic hazard for electronic components results in their damage or destruction
► Implement ESD safety measures at the workstation.
► Observe EN 61340 "Protection of electronic devices from electrostatic phenomena".
Required cable (accessories)
● Connection cable TPS - MVP
Procedure
► Connect the +24 V DC voltage supply (in accordance with rating plate) to the corresponding con-
necting socket.
Installation
21/42