Safety

Pictographs

Instructions in the 
text

Work instruction: here you have to do something. 

Symbols used

 Fore-vacuum flange

 Vacuum flange
 Exhaust flange

 Electric connection

Abbreviations used

TC:

 

 Electronic drive unit for turbopump

TM:

 

 Electronic drive unit and magnetic bearing controller for turbopump

TCP:

Electronic drive unit for turbopump, external with power supply

2

Safety

2.1

Safety precautions

Observe all safety and accident prevention regulations.

Regularly check the proper observance off all safety measures.

Do not loosen any plug connection during operations.

Keep leads and cables well away from hot surfaces (> 70 °C).

The unit has been accredited with protection class IP 65. Take necessary measures 
when installing into ambient conditions, which afford other protection classes.

Always ensure a safe connection to the protective earthing conductor (PE, protection 
class I).

Before carrying out any work disconnect the unit and all associated installations safely 
from the mains.

Prohibition of an action or activity in connection with a source of danger, 
the disregarding of which may result in serious accidents

Warning of a displayed source of danger in connection with operation of 
the unit or equipment

Command to perform an action or task associated with a source of dan-
ger, the disregarding of which may result in serious accidents

Important information about the product or this document

V

Duty to inform

Each person involved in the installation or operation of the unit must read and observe 
the safety-related parts of these operating instuctions.

The operator is obligated to make operating personnel aware of dangers originating 
from the unit or the entire system.

Summary of Contents for HiPace PM 071 282-X

Page 1: ...Translation of the original instructions Operating Instructions EN PT 0444 BEN A 1308 HiPace Backing pump relay box shielded...

Page 2: ...e 5 3 Product description 6 3 1 Relay box single phase 7 A 6 3 2 Relay box single phase 20 A 6 4 Electrical connection 7 5 Connection to the electronic drive unit 9 5 1 TC 110 9 5 2 TC 400 TM 700 9 5...

Page 3: ...Z 535 SEMI S1 ISO 3864 and DIN 4844 In this document the following hazard levels and information are considered Backing pump relay boxes Order number Relay box shielded for backing pumps 1 phase 7A fo...

Page 4: ...onditions which afford other protection classes Always ensure a safe connection to the protective earthing conductor PE protection class I Before carrying out any work disconnect the unit and all asso...

Page 5: ...1200 with Y Connector external electronic drive unit TCP 350 with adapter cable The shielded version supports the electromagnetic compatibility and reduces interac tion with other electric devices 2...

Page 6: ...um diaphragm vacuum pumps The maximum relay contact load is 7 A 3 2 Relay box single phase 20 A The relay box PM 071 283 X PM 071 285 X with mechanical relay is provided for the operation of larger Pf...

Page 7: ...r installation Electrical connection may be carried out only by trained and authorised electricians Ensure the system is adequately earthed Establish an adequate fuse protection on customer side depen...

Page 8: ...fittings Close the relay box 1 1a 12 1 1 11 11 S h i e l d AC in AC out 20 L1 N PE PE N L 3 1c 1b Fig 4 Relay box for backing pump single phase 20 A 1 Casing 1 1 Casing cover 1a Control lead for elect...

Page 9: ...T or via TCS 12 Make the settings and control via the interfaces of the electronic drive unit 5 2 TC 400 TM 700 Connect the control lead of the relay box directly to a vacant accessory port of the el...

Page 10: ...s of the electronic drive unit 6 Operation Establish the mains supply for the relay box Make sure the supply voltage for the backing pump is valid Observe the rating plates 6 1 Operation mode backing...

Page 11: ...he vacuum system via the function pumping station and await the run up Generate a fore vacuum pressure of 10 hPa by gas inlet via dosing valve Read and note the parameter P 316 Adjust the switch on th...

Page 12: ...12 Technical data 8 1 Dimensions Fig 5 Dimensions of the relay boxes 7 A and pattern of fixing holes 125 113 52 80 57 42 10 4 8 9 8...

Page 13: ...Technical data 13 Fig 6 Dimensions of the relay boxes 20 A and pattern of fixing holes 120 122 91 61 20 7 11 10 5 82 106...

Page 14: ...ty 2004 108 EC PM 071 282 X PM 071 283 X PM 071 284 X PM 071 285 X HiPace Harmonised standards and national standards and specifications which have been ap plied DIN EN 61000 3 2 2008 DIN EN 61000 3 3...

Page 15: ...e the only supplier of vacuum technology that provides a complete product portfolio Benefit from our know how and our portfolio of training opportunities We can support you with your plant layout and...

Reviews: