Fig. 6:
Permissible mounting orientation: Vertical direction of flow
5.3 Filling with lubricant
WARNING
Danger of poisoning from toxic vapors
Igniting and heating synthetic lubricants generates toxic vapors. Danger of poisoning if inhaled.
► Observe the application instructions and precautions.
► Do not allow tobacco products to come into contact with the lubricant.
NOTICE
Property damage from using non-approved lubricant
Attainment of product-specific performance data is not ensured. If non-approved lubricants are used,
all liability and warranty claims against Pfeiffer Vacuum are excluded.
► Use only lubricants approved by Pfeiffer Vacuum.
► Use alternative, application-specific lubricants only following consultation with Pfeiffer Vacuum.
Permissible lubricants
● D2 (standard lubricant)
● P3, optional
● F5 for corrosive gas model
● Other lubricants on request
The lubricant type is specified on the rating plate
► Please refer to rating plate of the vacuum pump for type and quantity of intended lubricant.
– Only the lubricant used during initial installation is permissible.
– D2 is permitted as a replacement for D1.
► Contact Pfeiffer Vacuum if you want to use another type of lubricant.
Required consumables
● Lubricant of the vacuum pump
Required tools
● Allen key,
WAF 8
● Ring spanner,
WAF 27
Required aids
● Collection receptacle
Installation
25/68