26
Fig. 6 - 06
X2
X2.2
X2.1
M6x16
A
X1
X2
X3
X6
X5
X7
X4
B
EcoDrive P74-ED-L
1
●
Connect all plugs as labelled on the control box
1
●
In the case of control unit EcoDrive
P74 ED-L
the adapter cable
X2
is to be connected to
socket
X2
. Plug
X2
.
1
is to be connected to the motor and plug
X2.2
. to the synchronizer.
●
The following ground cables must be attached in order to discharge static electricity.
●
Connect the earth cable from the superstructure (
480
mm)to the earthing connection
A
.
●
Join earthing connection
A
andearthing connection
B
with the earth cable (
700
or
100
mm).
●
Connect the earthing connection on the motor base with earthing connection
A
with the
earth cable (
700
mm)
●
On control
P74 ED-L
connect main switch and earthing connection
A
with the earth cable
(
500
mm).
●
Fasten the earth cable from plug
X1
to earth point
B
.
4
.15
Connecting the plug-in connections and earth cables
Installation