Adjustment
24V = 4% ED
2
.19
Mounting and dismounting the control unit
●
In order to dismount the control unit, pull plug
1
out of the socket of the motor control
plate or the control box as applicable.
●
Loosen screw
2
and remove linkage
3
from its slot.
●
Remove connecting rod
4
.
●
Loosen screws
5
and take off complete control unit.
●
In order to mount the control unit, position the needle bar at t.d.c
●
Put the control unit back on and tighten screws
5
slightly.
●
Activate engaging lever
6
manually, so that roller lever
7
engages with control cam
8
.
●
Align the control unit, so that the roller of roller lever
7
is centred in the cam notch
8
.
●
Tighten screws
5
firmly.
●
Replace connecting rod
4
and linkage
3
and tighten screws
2
firmly.
●
Plug in plug
1
.
●
Check performance manually.
●
If engaging lever
6
is not released, repeat adjustment of control unit
Fig. 2 - 14
1
3
2
4
5
6
5
5
7
8
2 - 16
Summary of Contents for 900/51