PEWA Megger TDR500 User Manual Download Page 2

VF

232.1m

0.67R

Battery State Indicator

Blinking signal gives the warning of low
battery  indicating when the battery volts
drop to 6.5V.

Cursor Position

This indicates the current cursor position in
metres or feet.

Velocity Factor Indicator

Indicates the current velocity factor as either
a ratio of the speed of light (R), or as m/

µ

s

or ft/

µ

s.

Menu

The menu allows the units of the distance
and velocity factor to be changed.

To enter the menu, switch the instrument on
holding down the warble key.

To change the displayed units, press one of
the velocity factor keys. The options 
available are m and Ratio, m and m/us,
ft and Ratio and ft and ft/us.

When selected, either switch the instrument
off, or press the warble key to start testing.

Cursor Left

This control moves the cursor to the left.

Range

This is a bi-directional range control. Press the left

side to decrease the gain, right side to increase.

Cursor Right

This control moves the cursor to the right.

Power

Pressing this button will turn the instrument on or

off depending on the current state.

Velocity Factor

Use this key to change the velocity factor to a

suitable value for the cable under test. 

Warble

Press to select the warble functions, or to return to

TDR functions. Warble function can be used to

trace cables.

VF

+

SPECIFICATION

Except where otherwise stated, this specification applies at an

ambient temperature of 20

O

C.

General

Ranges

30m, 100m, 300m, 1000m, 3000m.

(100ft, 300ft, 1000ft, 3000ft, 10,000ft.)

Accuracy

± 1% of range ± pixel at 0.67VF

[Note:- the measurement accuracy is 

for the indicated cursor position only 

and is conditional on the velocity factor 

being correct.]

Resolution

1% of range.

Input Protection

For connection to unenergised cable 

only.

Output Pulse

5 volts peak to peak into open circuit 

from 100

source. Pulse widths

determined by range and cable

impedance.

Gain

Automatic with gain and range.

Velocity Factor

Variable from 0.01 to 0.99

in steps of 0.01.

Refresh Rate

Three times a second.

Power Down

Automatic after 5 minutes

with no key press.

Warble

5V pk-pk from 100

, alternating 

between 810Hz and 1110Hz.

Batteries

Six LR6 (AA) type batteries, 

Manganese-alkali or nickel-cadmium

or nickel-metal-hydride cells.

Nominal Voltage

9V for Alkali or 7.2V for NiCad.

Battery Consumption

100mA nominal.

(30 hours’ continuous use.)

Safety

This instrument is to be used on

unenergised cable only.

EMC

Complies with Electromagnetic 

Compatibility Specifications

(Light industrial) BS EN 61326-1,with a 

minimum performance of ‘B’ for all 

immunity tests.