Installation and Operating Instructions for Bohemia Multi Fuel Stoves
Page
6 of 6
Provision must be made for easy sweeping of the chimney. A soot door can be built into a masonry chimney and flue
pipe is availab le with c leaning doors.
Any bend in the chimney or connecting fluepipe should not exceed 45º. 90º bends should not be used.
THE CHIMNEY CONNECTION
The flue p ipe for connecting the appliance to the chimney must be installed according to Build ing Regulat ions Approved
Document J and its diameter must be not less than the diameter of the outlet of the appliance. The fluepipe must be
adequately sealed to both the stove and the chimney to avoid any leakage.
We recommend a lso that no more than 1metre o f pla in un -insulated flue p ipe be used to connect to the chimney.
ALL CHIMNEYS SHOULD BE SWEPT AND INSP ECTED BEFORE INSTALLATION OF ANY APPLI ANCE
For re lin ing existing chimneys 316 or 904 grade stainless steel line rs or pumice ce ment liners in accordance with
Building Regulations Approved Document J should be used. Liners should be suitably insulated. We recommended that
any chimney relining is carried out by an experienced and competent installer who is HETAS registe red (see
www.hetas.co.uk
). The HETAS Gu ide to Approved Products and Services lists Chimneys and lining systems suitable for
use with solid fuel.
Sweeping through BOHEMIA
.
When installed with a top flue outlet it is possible to sweep through the Bohemia Stoves. Remove the baffle, and access
can be gained to the flue pipe.
VENTILATION
Adequate ventilation in the form o f a permanent air vent must be provided in accordance with build ing regulations
.
The BOHEMIA 60 requires a per mane nt air vent ope ningof minimum 550sq mm under B uildi ng Regulati ons.
Purpose made ventilation is not required on the 30, 40, and 50 models but sufficient adventitious ventilation must be
available.
COMMISSIONI NG
The installer should carry out the following checks and ensure that the stove is fully functional. We strongly
recommend that a first firing is included in the co mmissioning process
1.
Check a ll flue p ipe connections
2.
Check door latch mechanism
3.
Check door and glass seals are all intact and s ecure
4.
Warm chimney and check draught.
5.
Instruct customer in use of stove.
6.
Leave instructions for customer
7.
Check that after in itia l firing the door seals are not stuck to the body of the stove
Bohemia 30
Bohemia 40
Bohemia 60
Bohemia 50