TRANSPONDER IMMOBILISER
TRAINING MANUAL: JET FORCE
Page : 33/43
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Motocycles
TRANSPONDER IMMOBILISER
Precautions:
Check that the diagnostic plug jumper is fitted. The jumper provides the link between the immobiliser
module and the injection/ignition ECU, and is essential to be able to start the engine
If the jumper is not fitted, the transponder LED diagnostic is always the same (no link between the
immobiliser and the ECU)
Note: Fitting of a 5 k
Ω
resistive suppressor along with a resistive spark plug is essential for the proper
functioning of the engine
System programming
The machine is supplied with a red key (master) and a black key
The system is programmed in the factory
It is possible to program up to 7 black keys
The key memory procedure is the same as the AEC400 and ACI100 system
Reminder of the key memory procedure
1.
Using the red key, set the ignition to on, and when the LED lights, turn off the ignition
2.
Within a maximum of 15 seconds of cutting off the ignition with the red key, turn on the ignition with
the black key, and when the LED comes on turn off the ignition (repeat the operation for each black
key to be memorised (maximum of 7 black keys))
3.
Within a maximum of 15 seconds of turning off the ignition with the last key memorised, turn on the
ignition with the red key, and when the LED comes on, turn off the ignition
Key memory check
Using the red key, turn on the ignition, the LED on the instrument panel comes on for 0.5 seconds and
flashes a number of times. The number of flashes indicates the number of keys memorised, including the
red key
Additional information
Before carrying out any work on the transponder immobiliser, have the machine red key and black key to
hand
If the engine will not start, a first diagnostic may be carried out using the LED before checking the other
parts of the ignition system
Note: Do not remove the diagnostic plug jumper
In case of a fault, do not use an immobiliser module or ECU from another machine to carry out tests. The
keys, immobiliser module and ECU programmed on another machine form an assembly, are linked by a
code and must under no circumstances be separated
Important : If an ECU is changed without memorising the keys, do not turn on the ignition more than 16
times if the diagnostic jumper is disconnected as beyond this number, the ECU immobiliser function is
erased.