background image

BA

TTER

Y 6V

RF

A-6

7

Operating Guide

Manuel d’utilisation

Gebruiksaanwijzing 

Manual de funcionamiento

Guida all’uso

Gebrauchsanweisung

Brugervejledning

PRF-3004W-20

In-Ground Fence

 System

Système de clôture anti-fugue avec fi l

Omheiningssysteem met draad

Limitador de zona con cable

Sistema antifuga con fi lo

Rückhaltesysteme mit Draht

Nedgravet hegnsystem

Please read this entire guide before beginning

Veuillez lire ce manuel en entier avant de commencer

Gelieve deze gids volledig door te lezey voordat u begint

Por favor, este manual lea completo antes de empazar

Si prega di leggere attentamente la guida all uso prima di utilizzare il collare 

Bitte lesen Sie die gesamte Betriebsanleitung vor dem Trainingsbeginn

Læs venligst hele vejledningen, inden produktet tages i brug

Summary of Contents for PRF-3004W-20

Page 1: ...stema antifuga con filo R ckhaltesysteme mit Draht Nedgravet hegnsystem Please read this entire guide before beginning Veuillez lire ce manuel en entier avant de commencer Gelieve deze gids volledig d...

Page 2: ...ire In most areas this is a free service Do not install connect or remove your system during a lightning storm If the storm is close enough for you to hear thunder it is close enough to create hazardo...

Page 3: ...iscontinue use until the skin has fully healed You may need to trim the hair in the area of the Contact Probes Never shave the dog s neck this may lead to a rash or infection You should not make the c...

Page 4: ...________________________ Table of Contents Components 5 Other ItemsYou May Need 5 How the System Works 6 Key De nitions 6 Operating Guide Install the Fence Transmitter 7 Lay Out the System 7 Sample La...

Page 5: ...and ags Part PRFA 500 T ape measure Small Phillips screwdriver Drill mounting hardware Shovel or lawn edger Pliers Wire stripping pliers Scissors Lighter Gel lled Capsules Additional wire nuts W ater...

Page 6: ...c Correction signaling him to return to the Pet Area Boundary Width Combination of the Warning Zone and the Static Correction Zone Receiver Collar Receives the radio signal from the Boundary Wire Cont...

Page 7: ...e the Fence Transmitter indoors in a dry location only 1A 1B 1 m 3ft 1C __________________________________________________ Lay Out the System WARNING Underground cables can carry high voltage Have all...

Page 8: ...eed to be buried From the Fence Transmitter run the wire to A A to B B to C C to D D to E E to A twist the wires from A back to the Fence Transmitter See the Install the BoundaryWire section for more...

Page 9: ...nded that you cut and splice the BoundaryWire between each twisted section The signal cannot be cancelled by running the wire through plastic or metal piping Splicing shielded cable to the BoundaryWir...

Page 10: ...rning Zone at the maximum width 5 Plug the Power Adapter into the Power Socket and a working outlet The Power Adapter comes with the North American plug installed and additional plugs for the UK Europ...

Page 11: ...ow often your pet tests the system and receives a Static Correction Check the Receiver Collar every month to ensure the battery is working properly A replacement PetSafe battery RFA 67D 11 can be foun...

Page 12: ...Correction The numbers on the BoundaryWidth Control knob indicate signal strength and are not representative of BoundaryWidth footage If adjusting the Boundary Width Control knob does not give the des...

Page 13: ...can be attached to a chain link fence split rail fence or a wooden privacy fence The Boundary Wire can be attached as high as needed However make sure the BoundaryWidth is set at a high enough range f...

Page 14: ...raining The Contact Points must have direct contact with your pet s skin on the underside of his neck CAUTION Please read and follow the instructions in this manual Proper fit of the collar is importa...

Page 15: ...ed for good contact A collar that is too tight will increase the risk of pressure necrosis in the contact area 5 Allow your pet to wear the collar for several minutes then recheck the fit Check the fi...

Page 16: ...aining session Be sure to contain your pet by another means during the training period e g pen tie out lead etc During training if you need to take your pet out of the Pet Area remove the Receiver Col...

Page 17: ...to the Boundary Flags and if he decides to not move past the ags he is learning the system 11A __________________________________________________ Days 5 thru 8 Distraction Phase Perform three training...

Page 18: ...training is complete remove every other Boundary Flag every 4 days until all ags are removed Save Boundary Flags for future use __________________________________________________ Taking Your Pet Out...

Page 19: ...A to one half turn beyond finger tight Check the tightness weekly To Insert and Remove the Battery Please see Step 5 of this manual A To Set the Static Correction Level Read all steps before attempti...

Page 20: ...rrection Level 1 Remove the clear plastic cover with the edge of the Test Light Tool to expose the Correction Level Button D B C 2 With the battery installed press the Correction Level Button and rele...

Page 21: ...ction is produced by the Contact Points on the Receiver Collar not the Boundary Wire With proper use the system is safe for all I have a small pet and a large pet will this work for me Yes Since the P...

Page 22: ...smit through the walls of your house Make sure BoundaryWires are twisted from Boundary to the FenceTransmitter I have an inconsistent signal Make sure Fence Transmitter is at least 1 m 3 ft from large...

Page 23: ...iver Collar does not beep and the Test Light does not ash replace the battery in the Receiver Collar If it still does not beep and the Test Light does not ash contact the Customer Care Centre 11 If th...

Page 24: ...duct they shall be binding on you as if incorporated herein ___________________________________________ Compliance This equipment has been tested and found to comply with the EU R TTE Directive Before...

Page 25: ...ther patents pending 400 1194 00 1 2010 Radio Systems Corporation Layout Grid Sch ma d installation Ontwerpraster Cuadr cula de distribuci n Plantilla de montaje Plantilla de montaje Udl gningsnet 7 6...

Reviews: