8
Customer Care Center 1-800-732-2677
Step 3:
Strip the insulation from the ends of the
boundary wire, uncovering approximately 3/8-inch. Insert
the stripped ends of the boundary transmitter wires into
the two left red connector holes on the bottom of the
LP-4100 labeled “Loop”.
Note: There should be 1 wire in
each connector hole.
Depress the plastic tab, then insert the
wires and release the tab (
2A
).
Step 4:
Determine the length of wire needed to pass from
the Surge Protector to the wall transmitter. Measure and
cut 2 lengths of wire, then strip approximately 3/8-inch of
insulation at both ends. Twist the 2 lengths together, with
at least 10-12 twists per foot, so these wires will not send
out a signal.
LOOP TRANSMIT
TER
Push Tab
Down
Insert bare end
of wire into
opened slot
and release tab
to lock.
2A
Step 5:
Insert the ends of the transmitter wires into the right 2 black connectors at the
bottom of the Surge Protector labeled “Transmitter”.
Note: There should be 1 wire in each
connector hole.
Step 6:
Insert the opposite stripped ends of the two transmitter wires (from Step 5) into
the connectors on the wall transmitter.