background image

 

3.

 

Troubleshooting 

 

Problem 

Possible cause 

Solution 

Perun V3 cannot pass 
the calibration 
procedure 
successfully (a long 
sound signal is heard 
at the end of 
procedure and 
calibration is initiated 
at next start-up). 

Improper selector 
sticker position. 

Change selector sticker position. 

Loose selector lever (in 
AK replicas). 

Remove any slack, so that even slight selector 
lever movement will result in selector plate 
movement. 

Selector plate sensor 
malfunction. 

Send Perun V3 back for repair. 

Perun V3 does not 
detect any difference 
between „SEMI” and 
„AUTO” selector 
positions. 

Selector plate sensor 
needs to be calibrated. 

Enable calibration procedure at next start-up the 
following way: 

1)

 

remove gearbox from the body, 

2)

 

connect the motor, so that sound signals can 
be heard; fasten the motor to a heavy object, 
so that it will not jump around in case a signal 
to fire was received by Perun V3, 

3)

 

plug-in the battery, 

4)

 

enter the programming mode by touching the 
selector plate sensor and pulling it away 
twice, 

5)

 

pull the trigger 12 times and save the setting, 
so that at next start-up Perun V3 will enter 
calibration mode, 

6)

 

disconnect the battery and motor, 

7)

 

put gearbox back in body, put back pins and 
screw the pistol grip, 

8)

 

connect the motor, 

pass the calibration procedure. 

Loose selector lever (in 
AK replicas). 

Remove any slack, so that even slight selector 
lever movement will result in selector plate 
movement. 

Selector plate sensor 
malfunction. 

Send Perun V3 back for repair. 

Semi-automatic fire 
does not work 
(replica only fires 
bursts or fully 
automatic). 

Burst has been 
programmed on 
„SEMI” selector 
position. 

Program semi-automatic fire on „SEMI”. 

Sector gear optical 
sensor and/or sector 
gear LED diode are 
covered with grease. 

Remove grease from optical sensor and diode. 

Sector gear optical 
sensor and/or sector 
gear LED diode are 
damaged. 

Send Perun V3 back for repair. 

Summary of Contents for V3 Optical

Page 1: ...anual Table of contents 1 Basic information 2 2 Programming 2 2 1 Programming firing modes 3 2 2 Active brake AB 3 2 3 Precocking 4 2 4 Li Po protection 5 2 5 Double shot 5 2 6 Calibration mode 5 3 Troubleshooting 6 ...

Page 2: ... shown here https youtu be Z 3x6Ax3GAg Enter the programming mode by quickly switching the selector from SEMI to AUTO and back twice or the other way round from AUTO to SEMI and back twice In order to be able to enter the programming mode the selector must have been at rest for at least two seconds Successful entering into the programming mode is signaled by a sound signal Whether we enter the pro...

Page 3: ...he trigger 6 times Save changes by pulling and holding the trigger until a sound signal can be heard All the changes will be stored in memory and valid also after disconnecting and connecting the battery again 2 2 Active brake AB Active brake enter programming mode for any selector position pull the trigger 7 times and hold the trigger until a sound signal can be heard to save the settings Active ...

Page 4: ... spring will remain uncompressed during storage Precocking power enter programming mode for any selector position and pull the trigger 9 times Change the precocking power by switching the selector between SEMI and AUTO positions Hold the trigger until a sound signal can be heard to save the settings To precisely adjust the precocking power in replicas with different motors main springs and gears t...

Page 5: ...rt sound signals will be heard every 30 seconds 2 5 Double shot Double shot enter programming mode for any selector position pull the trigger 11 times and hold the trigger until a sound signal can be heard to save the settings When double shot feature is enabled if single fire mode is used shots will be fired both after the trigger has been pulled and relased 2 6 Calibration mode Calibration mode ...

Page 6: ...nd in case a signal to fire was received by Perun V3 3 plug in the battery 4 enter the programming mode by touching the selector plate sensor and pulling it away twice 5 pull the trigger 12 times and save the setting so that at next start up Perun V3 will enter calibration mode 6 disconnect the battery and motor 7 put gearbox back in body put back pins and screw the pistol grip 8 connect the motor...

Page 7: ... of plastic from between the trigger sensor and diode and putting it back then save the settings by removing the piece of plastic for a longer time so that at next start up Perun V3 will enter calibration mode 7 disconnect the battery and motor 8 put gearbox back in body put back pins and screw the pistol grip 9 connect the motor 10 go through the calibration procedure Replica fires a 2 round burs...

Page 8: ...stol grip Remove the cause of the friction The same battery and or motor didn t heat up earlier Low resistance MOSFET transistor and wiring used in Perun V2 provide resistance much lower than mechanical contacts and some other MOSFET circuits According to Ohm s law that allows more current to be drawn from the battery and directed to the motor This makes the trigger response and rate of fire faste...

Reviews: