33
EN
Mode
OK
Mode
OK
Set the blocked value of the
via
the
or
button.
maximum temperature
Press
to save and
move on to the subsequent
setting or keep the button
pressed for at least 4 sec to
save the new setting and
exit the programming
menu.
OK
Note: any previously blocked settings
are cancelled by setting
5.4 - TEMPERATURE ADJUSTMENT METHODS
t = 20,5 °C
Device is always off
t = 20,4 °C
Device is 1 min ON - 9 min OFF
t = 20,3 °C
Device is 2 min ON - 8 min OFF
t = 20,2 °C
Device is 3 min ON - 7 min OFF
t = 20,1 °C
Device is 4 min ON - 6 min OFF
t = 20,0 °C
Device is 5 min ON - 5 min OFF
t = 19,9 °C
Device is 6 min ON - 4 min OFF
t = 19,8 °C
Device is 7 min ON - 3 min OFF
t = 19,7 °C
Device is 8 min ON - 2 min OFF
t = 19,6 °C
Device is 9 min ON - 1 min OFF
t = 19,5 °C
Device always on
20,8
20,6
20,4
20,2
20,0
19,8
19,6
19,4
19,2
°C
0
10
2
4
6
8
Minutes
Device
OFF
Device
ON
Setting example: WINTER mode
T Set = 20 °C - Cycle = 10 minutes
Example: blocked Comfort minimum temperature setting for the
Summer mode (
)
cooling
The thermostat is factory set to work in
/
with a preset differential value (
) of
(adjustable from 0.2 °C to 1.2 °C).
The hysteresis value must be set according to the system's thermal
inertia; a low value is recommended for systems with radiators made of
e.g. cast iron and a high value for systems with fan coils.
DIFFERENTIAL MODE
ON OFF
Hysteresis
0,5 °C
A long cycle is recommended for systems with high thermal inertia (cast
iron radiators, floor systems) and a short cycle for systems with low
thermal inertia (fan coils).
As opposed to the differential, the temperature can be adjusted
(
) setting cycles from 7 to 20 minutes
(default 10 minutes)
This system maintains the desired temperature more stable, whilst
increasing the user's comfort sensation and saving on energy
consumption.
PROPORTIONALLY
PROP
Select the desired mode
5 - PROGRAMMABLE FUNCTIONS
Load
Time
°C
Off
On
On
Adjustable differential from
0.2 °C to 1.2 °C