7.2

 

Fitting

 

the

 

sprinkler

 

insert

 

 

 

Fit

 

O

ring

 

onto

 

flange

 

and

 

lightly

 

grease

 

for

 

easier

 

assembly.

 

 

Fit

 

sprinkler

 

module

 

inside

 

housing.

 

                         

Ensure

 

correct

 

alignment.

  

 

       

  
 

       

   

 

 

 
 
 

 

 
 

 

Push

 

flange

 

down

 

as

 

far

 

as

 

it

 

will

 

go.

 

 

Fit

 

retaining

 

ring.

 

                           

Retaining

 

ring

 

must

 

be

 

fully

 

inserted

 

into

 

the

 

slot.

 

 

 

Assemble

 

cover

 

with

 

sod

 

cup

 

by

 

mounting

 

the

 

cover

 

on

 

the

 

guide

 

housing

 

such

 

that

 

the

    

mark

 

of

 

the

 

guide

 

housing

 

and

 

cover

 

are

 

at

 

the

 

same

 

position.

 

Tighten

 

the

 

cover

 

with

 

three

 

(3)

 

sheetmetal

 

screws

 

(item

 

1).

 

 

Check

 

sprinkler

 

is

 

working

 

properly

 

as

 

per

 

point’s

 

5a

5b.

 

 
 

Guide

 

ribs

 

Guide

 

housing

  

Sprinkler

 

insert

 

Summary of Contents for Hydra D-H-TC

Page 1: ...CALW GmbH Industriestra e 19 29 D 75382 Althengstett Germany Phone 0049 7051 162 0 Fax 0049 7051 162 133 E mail perrot perrot de E mail Technical Department technik perrot de Maintenance and Operating...

Page 2: ...rot de Contents 1 SAFETY 3 1 1 HOW INSTRUCTIONS ARE MARKED IN THIS MANUAL 3 1 2 HAZARDS OF IGNORING SAFETY INSTRUCTIONS 3 2 DESCRIPTION 4 3 INSTALLATION 5 4 SPECIAL TOOLS 5 5 COMMISSIONING PREPARING F...

Page 3: ...lease follow both the general safety instructions specified in this safety section and the specific safety warnings included in other sections 1 1 How instructions are marked in this manual Safety ins...

Page 4: ...lthengstett Germany Phone 0049 7051 162 0 Fax 0049 7051 162 133 E mail perrot perrot de E mail Technical Department technik perrot de 2 Description View from above Side view Plug for cover fastening s...

Page 5: ...with Teflon tape Note Part circle sprinklers must be set up in such a way that the mark is aligned in a straight line from the left side of the irrigation sector A dot is located on the border of the...

Page 6: ...ly is open and the maximum operating pressure has been reached check sprinkler and connection for leaks Sprinkler head rises and begins to rotate Do not stand facing the nozzle opening 5 2 Preparing f...

Page 7: ...r adjustment screws are located under the cover with sod cup on the Hydra M TC version the cover must be disassembled to make irrigation sector adjustments First remove the plug and then the coder fas...

Page 8: ...D 75382 Althengstett Germany Phone 0049 7051 162 0 Fax 0049 7051 162 133 E mail perrot perrot de E mail Technical Department technik perrot de Set right side stop position Right stop position can be...

Page 9: ...51 162 133 E mail perrot perrot de E mail Technical Department technik perrot de Note In order to speed up the setting of the irrigation sector the sprinkler head can be manually turned forward with t...

Page 10: ...er with sod cup by unscrewing the three 3 sheet metal screws item 1 using a Torx key Pull the cover off in an upward direction Disassemble sprinkler head cover with sod cup by unscrewing the central c...

Page 11: ...an be assembled with a tail nozzle This nozzle can be refitted or and also closed with a corresponding plug Put O ring over the new nozzle and reversing the procedure re install in the sprinkler head...

Page 12: ...nozzle Adjust as follows Take off inlet nozzle and filter together by using a screwdriver to lever up the inlet nozzle at the notch Snap inlet nozzle back onto the sprinkler module so that the elonga...

Page 13: ...grease for easier assembly Fit sprinkler module inside housing Ensure correct alignment Push flange down as far as it will go Fit retaining ring Retaining ring must be fully inserted into the slot Ass...

Page 14: ...r 9 Troubleshooting Malfunctions Problem Cause Remedy Stop valve fails to close completely Bits of dirt between sealing plate and stop valve Clean stop valve seat and sealing plate Rotary speed too lo...

Page 15: ...2016 Page 15 16 Perrot REGNERBAU CALW GmbH Industriestra e 19 29 D 75382 Althengstett Germany Phone 0049 7051 162 0 Fax 0049 7051 162 133 E mail perrot perrot de E mail Technical Department technik pe...

Page 16: ...051 162 133 E mail perrot perrot de E mail Technical Department technik perrot de F r weitere Informationen stehen wir Ihnen gerne zur Verf gung We remain at your full disposal for any further informa...

Reviews: