Protection System

Your Audiant 80i integrated amplifier protection systems to ensure reliability and long life of the unit and 
the speakers it is connected to. The protection system comprises of five main protection methods.  In all 
instances the protection state will be indicated by all source input LEDs flashing.  Power to the amplifier will 
need to be cycled, by the standby button or power switch, to reset the protection state.

DC Offset Detection

The DC offset detection system offers loudspeaker protection if the output of the amplifier goes to a high 
DC voltage.

Over-Temperature Detection

The over-temperature detection system constantly monitors the heat generated by the output MOSFETs. 
If the monitored temperature reaches 80°C (176°F) the output to the speakers will be disconnected to stop 
the temperature from rising further.

An over-temperature condition is normally caused by a combination of high listening levels, low impedance 
or low sensitivity speakers.

Fuse Fail Detection

The fuse fail detection system monitors the internal DC rail fuses.  If any of the fuses should blow the output 
to the speakers will be disconnected to protect the speakers and amplifier from damage.

Fuses normally blow for a reason.  Any doubts about fuse failure should be conveyed directly to your 
Perreaux dealer.

AC Fail Detection

The AC fail detection system monitors the AC voltage on the main power transformer.  If for any reason 
the AC mains voltage is lost, e.g. power failure or tripped circuit breaker, the speakers are immediately 
disconnected from the amplifier before the amplifier loses power.

Over-Current Detection

The over-current detection system ensures the output devices are constantly operating within their safe 
operating limits and provides a fast response to temporary overload conditions.  When an over-current condition 
is detected the output to the speakers is disconnected to isolate the amplifier from potential damage.

An over-current condition can occur due to a short across the speaker terminals, a speaker driver/crossover 
fault or excessive current demand due to low impedance speakers.

Care and Maintenance

The 80i has been designed to provide many years of trouble free enjoyment. It is important to keep the 
exterior of the unit clean.

Notes: 

Always switch the unit off and remove the power cord from the rear of the amplifier before 

attempting to clean your Audiant 80i integrated amplifier in the manner described below.

Never apply liquid directly to the amplifier. 
Never use abrasives. 
Never rub in a circular motion.

Front Panel and Cover

The front panel and cover feature a durable, high-quality anodised finish. To remove finger marks and dirt, 
simply rub the surface with a soft cloth.

If the dirt is not removed, use a small quantity of isopropyl alcohol on a clean cloth and rework the effected area.

9

Summary of Contents for Audiant 80i

Page 1: ...Owners Manual Audiant 80i Integrated Amplifier...

Page 2: ...plied with a non rewireable mains plug for the intended country Replacement mains leads can be obtained from your Perreaux dealer Should you need to change the plug please dispose of it carefully A pl...

Page 3: ...supply only of the type described in the operating instructions and or as marked on the rear of the unit DO NOT defeat the safety earth of the grounding type mains plug severe injury or death may res...

Page 4: ...t integrated amplifier you will discover many more of the musical secrets we strive to reveal From all of us at Perreaux thank you for choosing the Audiant 80i integrated amplifier INTRODUCTION 3 INST...

Page 5: ...iod of time its temperature may rise above the designated operating level and the over temperature protection will trip see Protection System section Other Devices Ideally your Audiant 80i integrated...

Page 6: ...replace this fuse with another of the same type and rating 3 Mains Fuse The mains fuse is user serviceable and should always be replaced with the same type and rating see Technical Specifications pag...

Page 7: ...peakers 9 HT Loop Input The Home Theatre Loop is used to integrate the Audiant 80i into a home theatre system that has preamp outputs on the surround processor or receiver Please ensure the volume lev...

Page 8: ...it may be recorded The input should not be changed whilst recording 3 Volume Control The Volume Control increases decreases the level of the sound from the outputs of the amplifier This control affec...

Page 9: ...a computer using the USB input the Skip Forward key allows you to skip forward by one track in the music application running on the computer The USB input must be selected for this to function 7 Stop...

Page 10: ...Detection The AC fail detection system monitors the AC voltage on the main power transformer If for any reason the AC mains voltage is lost e g power failure or tripped circuit breaker the speakers ar...

Page 11: ...uzz or hum Ensure no interconnects are loose or defective Ensure that your tape deck turntable is not too close to the amplifier Unable to make or play tape recordings Check Line Out has been connecte...

Page 12: ...8 130Wrms into 4 Total Harmonic Distortion THD N Typically 0 002 1kHz 80W into 8 20Hz to 20kHz 0 05 80W into 8 0 05 1W into 8 Frequency Response 0 1dB 20Hz to 20kHz Signal to Noise Ratio A weighted 10...

Page 13: ...BFS 20Hz to 20kHz 0 004 20dBFS Frequency Response 0 2dB 20Hz to 20kHz Signal to Noise Ratio A weighted 120dB ref 0dBFS Phono Stage Gain 40dB Input Impedance 47k Input Capacitance 100pF Total Harmonic...

Page 14: ...Dimensions 431mm 17 0 67mm 2 6 309mm 12 2 13...

Page 15: ...________________________________________________________________________________________________ _____________________________________________________________________________________________________ _...

Page 16: ...Perreaux Industries Ltd PO Box 305 Mosgiel Dunedin 9053 New Zealand T 64 3 489 2975 F 64 3 489 2976 E nz info perreaux com W www perreaux com...

Reviews: