background image

Inception Operation Manual

2

Important Safety Information

WARNINGS:

-  DO NOT REUSE. This cushion is designed to be 

uniquely shaped to its user. DO NOT use this cushion 

for another individual. 

-  Follow all instructions and safety information 

provided with the product and provided by the 

manufacturer of the wheelchair or other accessories. 

-  DO NOT use the components of this product 

separately. Assemble and use this product only as 

instructed in this manual.

Immediately consult qualified personnel if there are 

any signs of user discomfort or fear associated with 

using the product.

-  Before long-term use of the product, and for the 

first few weeks, the user should sit for shorter, 

introductory periods of time, and ONLY under 

supervision. During introductory sitting, the skin 

should be carefully monitored, while the user adjusts 

to the new shape and positioning. 

-  Skin/soft tissue breakdown can occur due to a 

number of factors, which vary by individual. Check 

skin frequently, at least once a day. Redness, bruising, 

or darker areas (when compared to normal skin) may 

indicate superficial or deep tissue injury and needs 

to be addressed. If there is any discoloration to skin/

soft tissue, STOP USE immediately. If the discoloration 

does not disappear within 30 minutes after disuse, 

immediately consult a healthcare professional.

-  The cushion must always be used with a 

compatible cover.

-  DO NOT place obstructions between the individual 

and the cushion. The cushion, the air insert, and 

the cover MUST be compatible sizes and MUST 

be used as directed in this manual. Except for the 

compatible covers listed in “Product Specifications” 

in this manual, placement of any items between 

the individual and the cushion: 1) may reduce or 

eliminate the benefits of the cushion, increasing 

the risk to skin or to other soft tissue, and 2) may 

cause the individual to become unstable and 

vulnerable to falling.

-  DO NOT use the cushion on top of, or in 

conjunction with, any other products or materials, 

except as indicated in this manual. Using non-

compatible products or materials, whether inside 

or outside the cover: 1) may reduce or eliminate 

the benefits of the cushion, increasing the risk to 

skin or to other soft tissue, and 2) may cause the 

individual to become unstable and vulnerable to 

falling. 

-  If you are unable to perform any tasks described 

in this manual, seek assistance by contacting 

a clinician, equipment provider, distributor, or 

Customer Support.

Intended Use

The Comfort Inception Cushion (Inception) is a custom-made, ready-to-use, wheelchair seating surface that is 

constructed as prescribed to meet the needs of a specific user in a specific wheelchair. The Inception must be 

properly sized and configured to the individual and must be used with a compatible cover. 

The STRETCH-AIR Cover is a fluid-resistant textile enclosure intended to protect the cushion from solid debris 

or liquids. 

The COMFORT-TEK Cover is a fluid-resistant textile enclosure intended to protect the cushion from solid debris 

or liquids. 

The Incontinence Liner is a fluid-resistant textile enclosure intended to be used with a STRETCH-AIR Cover or 

COMFORT-TEK Cover to further protect the cushion from liquids.

A clinician who is experienced in seating and positioning, along with a full risk assessment and program of care, should 

determine whether the product is appropriate for the individual’s particular seating needs. The product’s intended use 

statement alone should not be relied upon to make that determination.
The medical products featured in this document are intended to be only one part of an overall care regimen that 

includes all seating and mobility equipment and therapeutic interventions. A clinician who is experienced in seating 

and positioning should identify this care regimen after evaluating the individual’s physical needs and overall medical 

condition.
A clinician should also evaluate for visual, reading, and cognitive impairment to determine the need for caregiver 

assistance or the need for other assistive technology, such as large-print instructions, to ensure proper product use.

Summary of Contents for Inception

Page 1: ...Inception OPERATION MANUAL ...

Page 2: ......

Page 3: ...tes not following the specified procedure could lead to potentially hazardous conditions resulting in minor to moderate injury or damage to the equipment or other property Incident Reporting In the event of a serious incident or injury contact Customer Support Symbols Glossary Manufacturer Date of manufacture Consult instructions for use Please Note Supplier These instructions must be given to the...

Page 4: ...th any other products or materials except as indicated in this manual Using non compatible products or materials whether inside or outside the cover 1 may reduce or eliminate the benefits of the cushion increasing the risk to skin or to other soft tissue and 2 may cause the individual to become unstable and vulnerable to falling If you are unable to perform any tasks described in this manual seek ...

Page 5: ...priate precautions especially when the cushion will contact unprotected skin Keep small components out of the reach of children and any individuals who have a tendency to place inedible objects in their mouths Swallowing or inhalation may lead to serious injury or death IMMEDIATELY seek emergency medical assistance WARNINGS MOTOR VEHICLE TRANSPORTATION Failure to pay attention to these warnings co...

Page 6: ... optional component Repair Kit HP45 Hand Pump Inception Each Inception is uniquely constructed An example is shown with a COMFORT TEK Cover Standard Anti Thrust Growth Kit WARNING The Inception may have been ordered to include a Standard Anti Thrust Growth Kit CD AT STND GROWTH KIT which is foam pieces that can be removed and replaced as prescribed The foam pieces must be correctly aligned and sec...

Page 7: ...g in the Incontinence Liner if using B Cover required The COMFORT TEK Cover is shown C Incontinence Liner optional A The ROHO Air Insert valve hose is located in the back of the cushion Covering s for the Inception that includes a ROHO Air Insert Inception Placement WARNINGS The cushion must be used with compatible covering s DO NOT use the Incontinence Liner alone it must be used with a cover Ins...

Page 8: ...hanges in altitude may require adjustment to the air insert DO NOT expose the air insert to temperatures above 70 C 158 F which may accelerate aging and cause product damage If the air insert has been in temperatures lower than 32 F 0 C and exhibits unusual stiffness allow to warm to room temperature Rigid Insert Removable Version WARNINGS Follow these instructions for the correct placement of the...

Page 9: ...Hand Check During a Hand Check you will use the width of the fingers to see if the air cells are properly inflated When the air cells are properly inflated the user is both immersed in the air cells and supported by the air cells a Slide your hand between the air cells and the user and feel for the user s lowest bony prominences b Refer to the Hand Check Guide below to adjust the air insert The re...

Page 10: ...d tumble dry low 40C Or Disinfecting Hand wash the cover with water and bleach using 1 part household liquid bleach per 8 parts warm 40 C 104 F water Rinse thoroughly with clean water and line dry Let dry completely before use Or Machine wash hot using common laundry detergent and tumble dry low 60C Or Foam Components WARNING Disinfectants are NOT effective on porous surfaces such as foam DO NOT u...

Page 11: ...he bleach solution for 10 minutes Rinse thoroughly with clean water Let dry completely before use Care Symbols Wipe with a damp cloth Hand wash Dry flat Line dry Hand wash warm Tumble dry low Bleach 1 part bleach 8 parts water Dry flat in the shade 40C Machine wash warm gentle 60C Machine wash hot normal at the temperature shown Bleach 1 part bleach 9 parts water Inception Operation Manual 9 Maint...

Page 12: ...ectly placed on the cushion The air cells and the top of the cover should face up The air insert should be centered beneath the user After checking all of the above allow the individual at least one hour to adjust to the air insert Not sure about orientation of the cushion and covering s Orientation Guide The covering s should be oriented with the zipper in the back of the cushion If the foam is c...

Page 13: ...en misused damaged by an accident or damaged from an act of Nature e g flood tornado earthquake fire Any substitutions of supplied product accessories or modification to the product will void the warranty What the customer must do Contact Customer Support Items sent without prior authorization will not be returned to the customer Disclaimer and Limitation of Warranties Any implied warranties inclu...

Page 14: ......

Page 15: ......

Page 16: ...OM INCEPTION AMR 2021 04 14 1960 South Calhoun Rd New Berlin WI 53151 USA permobil com ...

Reviews: