Perma Pure LLC 

Tel:  732-244-0010 

1001 New Hampshire Ave 

Tel:  800-337-3762 

(toll free US)

 

Lakewood, NJ 08701 

Fax:  732-244-8140 

www.permapure.com

 

Email:  [email protected] 

 

I

NSTRUCTION 

M

ANUAL

 

 

 

HEATED FILTER PROBES 
G

ENERAL 

P

URPOSE 

S

ERIES

 

Model 34C-MONSOL 

 

Version 4.05 

 

Summary of Contents for Baldwin series

Page 1: ...LC Tel 732 244 0010 1001 New Hampshire Ave Tel 800 337 3762 toll free US Lakewood NJ 08701 Fax 732 244 8140 www permapure com Email info permapure com INSTRUCTION MANUAL HEATED FILTER PROBES GENERAL PURPOSE SERIES Model 34C MONSOL Version 4 05 ...

Page 2: ...TABLE OF CONTENTS Table of Contents 2 A Specifications 3 B Limited Warranty 4 C Principle of Operation 5 D Maintenance 6 E Troubleshooting 7 F Spare Parts 8 Appendix 9 ...

Page 3: ...oil Dimensions 14 x 12 x 8 HWD w o Stinger probe Weight 34 lbs Operating Specifications Calibration Gas Requirement 20 psig 6 10 LPM Probe Operating Temperature 375ºF 190ºC Blowback Duration 5 sec standard 30 sec maximum Blowback Valve 24 VDC Blowback Flowrate 14 scfh Instrument Air for Blowback Min 50 psig Max 90 psig Material Specifications Enclosure Material NEMA 4 Steel Probe Stinger 316L SS t...

Page 4: ...irable for any particular use or application 2 Buyer takes sole responsibility for the use and applications to which the product is put and Buyer shall conduct all testing and analysis necessary to validate the use and application to which Buyer puts the product for which Buyer may recommend the use or application of the product by others and 3 the characteristics specifications and or properties ...

Page 5: ...a stack or duct with a 1 Schedule 40 male pipe nipple This pipe nipple can be screwed into a standard ASA flange either flat or raised face The probe boot can be heat shrunk to the sample line to eliminate cold spots Blowback The Model 34C comes with a blowback air accumulator tank and 2 way solenoid To operate blowback connect a 50 90 psig instrument airline to the blowback air accumulator tank T...

Page 6: ...njunction with the Baldwin Series Flow Control Drawer monitoring the sample vacuum will warn the operator when to change the filter element The operator should log the beginning sample vacuum when the system is first started up Keeping a daily log of the sample vacuum will notify the operator what frequency of blowback is required and when increasing frequency of blowback is ineffective in reducin...

Page 7: ...open for heater resistance the fusible link has blown and the jacket should be replaced Filter plug cannot be removed from filter housing Check O rings for damage High particulate loading Replace O rings Clean the O ring sealing surfaces with a clean towel prior to reassembly Air from blowback tank keeps leaking onto sample when not activated Voltage going to solenoid is 15VAC or less Disassemble ...

Page 8: ...ment 316L SS 1 25 x 2 975 10 Micron 3PAM 006PK Gasket Graphoil 1 25 10 pack 3PHS 417 Heater Cartridge 350W 3PAM 028PK O Ring Silicone 50 Durometer 10 pack 3PAM 010PK O Ring Viton 50 Durometer 10 pack 3PAM 031PK O Ring Pack Viton C series probes only 5 ea 1 OD 2 OD 2VRS 008 Valve Check Viton O Ring 2VS2 015 Valve Solenoid 2 Way 24VDC 316SS ...

Page 9: ...9 APPENDIX ...