Models: HP15BO, BS, RO, RS, TO, TS, HK15BO, RO, TO
Electronic Control:
Dixell (XR60CX)
Defrost Style:
Programmed Defrost (12 hours--15 minutes)
Cabinet Lighting:
Lights are controlled through a manual on/off switch as well as
through the door switch.
Evaporator Fan:
Is controlled by the door switch during Cooling Mode
LOAD
COOLING MODE
OFF MODE
DEFROST MODE
Compressor
Energized
De-Energized
De-Energized
Condenser Fan
Energized
De-Energized
De-Energized
Evaporator Fan
Energized
De-Energized
Energized
Models: HP15WO, WS, HK15WO
Electronic Control:
Dixell (XR60CX)
Defrost Style:
Off Cycle Defrost
Cabinet Lighting:
Lights are controlled through a manual on/off switch as well as
through the door switch.
Evaporator Fan:
Is controlled by the door switch during Cooling Mode
LOAD
COOLING MODE
OFF MODE
DEFROST MODE
Compressor
Energized
De-Energized
N/A
Condenser Fan
Energized
De-Energized
N/A
Evaporator Fan
Energized
Energized
N/A
Return to
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Table 8-11. HP15BO, BS, RO, RS, TO, TS, HK15BO, RO, TO Load Operation Modes
Table 8-12. HP15WO, WS, HK15WO Load Operation Modes
Electrical System Repair Instructions