Perlick Draft Arm Installation Instructions Manual Download Page 18

PERLICK CORPORATION

   8300 W. Good Hope Road,  Milwaukee, WI  53223   •   800.558.5592   •   perlick.com

PRODUCT INSTALLATION INSTRUCTIONS

   

   Dispensing Towers

DISPENSING TOWERS

DRAFT ARMS, 2-6 FAUCET TEE TOWERS, LUCKY AND PANTHER TOWERS

18

LUCKY AND PANTHER TOWER INSTRUCTIONS, Continued

Attaching the Beer Line to the Lucky or Panther Towers

1.  On one end of the beer connector, cut off 

the beer nut fitting. 

2.  Push the beer line connector end over the 

barbed end of the product supply line and 

tighten with a clamp using a 1/4” nut driver or 

slotted screwdriver.

3.  Insert the rubber washer into the other end 

of the beer line and attach to the keg coupler.  

Tighten with an adjustable wrench but do not 

over-tighten.
4.  Repeat for each additional supply tube.

Attaching the Gas Line Tubing

1.  Attach one end of the gas line to a valve on the air distributor  

manifold and tighten with a hose clamp. 
2.  Repeat for each additional product line.
3.  Attach the other end of the gas line to the keg coupler and tighten 

with a hose clamp.

Attaching the Tapping Hole Covers

1.  To comply with NSF standards, please attach the tapping hole covers provided.  
2.  The two-piece cover can be adjusted to tighten snugly around beer lines and air scoop  

tubing.
3.  Position the covers tightly around the tubing and mount to the bottom side of the cabinet 

top using a cordless drill with a 5/16” socket head bit and the self-drilling screws provided. 

Please refer to Diagram 7 in the Appendix.

3

1

3

1

2

2

1

1

3

Summary of Contents for Draft Arm

Page 1: ...ctions Dispensing Towers Draft Arm Lucky Panther or Tee Towers PERLICK CORPORATION 8300 W Good Hope Road Milwaukee WI 53223 800 558 5592 perlick com Form No Z2351 Rev 04 17 19 TeeTower LuckyTower Pant...

Page 2: ...ers 11 Mounting the Beer Wine Drainer to a Cabinet Top 11 Mounting the Beer Wine Drainer to a Counter Top 12 Running the Air Scoop Tubing to the Draft Arms or Tee Towers 12 Attaching the Beer Line to...

Page 3: ...re installing you may have parts left over after the installation is complete Tools and Materials Required Safety glasses Rubber gloves Utility knife or vinyl tubing cutter Slotted screwdriver 1 4 nut...

Page 4: ...IONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 4 Dispensing Kit Component Parts Continued Air Distributor Cover 68678 1 DZS36 Air Distributor Cover...

Page 5: ...pensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 5 Dispensing Kit Component Parts Continued Faucet Head Assembly 408X Stainless Steel Wine Faucet Head 408XSS...

Page 6: ...STRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 6 Dispensing Kit Component Parts Continued Tapping Parts Kit 67305 Tapping Parts Kit Wine 67305...

Page 7: ...INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 7 Air Scoops for Field Retrofit Kits R only see page 9 Air Scoop 69315 1 For BBR...

Page 8: ...ss there are at least two safety mechanisms in the pressure system At least one at the regulator and one at the product container coupler NEVER Connect a pressurized gas cylinder directly to a keg NEV...

Page 9: ...apply to are shown on page 7 2 Knock out the desired slug from the air scoop and insert the 1 snap bushing 3 Secure the air tube in place by attaching a cable tie on each side of the snap ring 4 Mount...

Page 10: ...to be drilled during field instal lation templates are available at www perlick com bar beverage equipment specifications downloads tower and drip pan templates 2 Factory provided tapping holes will...

Page 11: ...lastic nut Take caution not to over tighten 2 Attach the nylon reducing bushing to the drainer until hand tight 3 Attach the nylon elbow to the reducing bushing 4 Slide the 1 2 ID anti microbial drain...

Page 12: ...ng and unloading kegs 3 Route the anti microbial tubing to the beer wine collection drain or waste container It may be routed to the floor drain located in the right rear corner of the cabinet It must...

Page 13: ...nto the other end of the beer line and attach to keg coupler Tighten with an adjustable wrench but do not over tighten 3 Repeat for each additional supply tubes Attaching the Wine Line to Draft Arms o...

Page 14: ...air scoop tubing 3 Position covers tightly around tubing and mount to the bottom side of the cabinet top using a cordless drill with a 5 16 socket head bit and the self drilling screws provided Please...

Page 15: ...e drilled during field installation templates are available at http www perlick com bar beverage equipment specifications downloads tower and drip pan templates 2 Insert the threaded mounting shaft th...

Page 16: ...Attach the nylon elbow to the reducing bushing 4 Slide the 1 2 ID anti microbial drain tubing over the barbed end of the nylon elbow 5 Use the nylon hose clips and self drilling screws to secure the...

Page 17: ...container It may be routed to the floor drain located in the right rear corner of the cabinet It must then be plumbed to an external drain There are also knockouts provided on the cabinet ends as othe...

Page 18: ...upler Tighten with an adjustable wrench but do not over tighten 4 Repeat for each additional supply tube Attaching the Gas Line Tubing 1 Attach one end of the gas line to a valve on the air distributo...

Page 19: ...alled It can be easily removed to access the valves on the air distributor 2 Each end of the cover has a knockout to provide clearance for the gas line Remove the appropriate knockout 3 Route the gas...

Page 20: ...od Hope Road Milwaukee WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 20 APPENDIX DIA...

Page 21: ...Good Hope Road Milwaukee WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 21 APPENDIX D...

Page 22: ...ee WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 22 APPENDIX DIAGRAM 3 Drip Pan Drai...

Page 23: ...WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 23 APPENDIX DIAGRAM 4 Air Distributor...

Page 24: ...od Hope Road Milwaukee WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 24 APPENDIX DIA...

Page 25: ...e WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 25 APPENDIX DIAGRAM 6 Air Sleeve Ins...

Page 26: ...W Good Hope Road Milwaukee WI 53223 800 558 5592 perlick com PRODUCT INSTALLATION INSTRUCTIONS Dispensing Towers DISPENSING TOWERS DRAFT ARMS 2 6 FAUCET TEE TOWERS LUCKY AND PANTHER TOWERS 26 APPENDIX...

Page 27: ...NCENTRIC COOLER TOP GRANITE TOP 4 1 4 5 PROPERTY OF THE PERLICK CORP NOT TO BE COPIED OR USED DETRIMENTAL TO OUR INTERESTS VIN SERVICE AIR COOLED TOWERS MOUNTING REFE Lucky and Panther Tower Mounting...

Reviews: